HomeMy WebLinkAbout414 PLOWMAN WAY - SPECIAL INSPECTIONS - 6/5/2002June 5, 2002 KB Home 8401 East Belleview Avenue Suite 200 Denver, Colorado 80237 Attn: Mr. Kobey Northen Re: Exterior Perimeter Drain Observation Warren Farms P.U.D. 3rd Filing 414 Plowman Court — Lot 118 Fort Collins, Colorado Terracon Project No. 20005081 Mr. Northen: Irerracon 301 N. Howes • P.O. Box 503 Fort Collins, Colorado 80521-0503 (970) 484-0359 Fax: (970) 484-0454 A representative of Terracon observed the perimeter drain construction at the referenced site on May 31, 2002, as requested. A four -inch diameter perforated PVC pipe had been placed around the exterior perimeter of the crawl space foundation system. The drainage pipe appeared to exhibit positive drainage toward the sump pump located within the crawl space area of the residence. We also observed 1 Y2 inch washed aggregate placed above and below the pipe. The waterproof dampening of the foundation system was also observed and in our opinion was completed in general accordance with standard residential practices. In our opinion the exterior perimeter drain was constructed in general accordance with the plans and specifications for this project. Sincerely, TERRAC enn R' Senior Field Technician Copies to: (2) Addressee ;a 712 e David A. Richer, P.E;; Geotechnical Engineer/ "` ment Manager Arizona ■ Arkansas ■ California ■ Colorado ■ Georgia ■ Idaho ■ Illinois ■ Iowa ■ Kansas ■ Kentucky ■ Minnesota ■ Missouri Montana ■ Nebraska ■ Nevada ■ New Mexico ■ Oklahoma ■ Tennessee ■ Texas M Utah ■ Wisconsin ■ Wyoming Consulting Engineers & Scientists Since 1965 www.terracon.com