PLAZA
ENGINEERING ENGINEER'S FIELD REPORT
CONSULTANTS
Report Date: August 29, 1998 Report No.: 9
Project: IV= COMMY Stanton Creek P_U_D., Filing 1 (Units 25-30)
Location: 6802 Antigua Drive, Fort Collins, Colorado.
Architect: Knudson Gloss Architects and Planncrs, Boulder, Colorado
Contractor: James Company, Boulder, Colorado (Scott Holmes)
Subject: Concrete Foundation Watts
Date: August 24, 19" (1:00 pm)
Weather: Warm
OBSERVATIONS
In gam, the size, bw and placement of the reinforcing steel is consistent with the structural
Gr�rade outlined in the contract drawings. The horizontal reinforcement consists of No. 5,
40 steel, while the vertical is were No. 4, Grade 60 reinforcing bar. All reinforcement
was tied together properly, with laps at splices and corner bars being 24 inches in length
FIELD ]IMSTRUCTIOIVS GIVEN
None.
cc:
F.
F. Plaza, P
PLAZA ENGINEERING CONSULTANTS, INC.
P.O. Box 1002 Loveland, CO 80539-1002 (970)-663-6353 (970) 663-0368 Fax