ENGINEER'S FIELD REPORT
Report No.: 9
Project. James Company Stanton Creek P.U_D., Filing i (Units 25-30)
Location: 6902 Antigua Drive, Fort Collins, Colorado.
Architect' Knudson Gloss Architects and Planners, Boulder, Colorado 97
Contractor. James Company, Boulder, Colorado (Scott Holmes)
Subject: Concrete Foundation Walls
Date: August 24, 1998 (1:00 pm) Weather: Warm
OBSERVATIONS
In general, the size, type and placement of the reinforcing steel is consistent with the st wural
requirements outlined in the contract drawings. The horizontal reinforcement consists of No. 5,
Grade 40 steel, wbile the vertical dowels were No. 4, Grade 60 reinforcing bar. All reinforcement
was tied together properly, with laps at splices and corner bars being 24 inches in length.
FIELD INSTRUCTIONS GIVEN
=1
Field
S , F. Plaza, P
Pr
�NAt. to
cc: FF e
PLAZA ENGINEERING CONSULTANTS, INC.
P.O. Box 1002 Loveland, CO 80539-1002 (970)-663-6353 (970) 663-0368 Fax
TOTAL P.01