HomeMy WebLinkAbout6802 ANTIGUA DR - SITE PLANS - 7/30/1998 (9)PLAZA
ENGINEERING
CONSULTANTS
Report Date: August 29, 1998
ENGINEER'S FIELD REPORT
Report No.: 9
Project: James Company Stanton Creek P.U.D., Filing 1 (Units 25-30)
Location: 6802 Antigua ]give, Fort Collins, Colorado.
Architect: Knudson Gloss Architects and Planters, Boulder, Colorado
Contractor. James Company, Boulder, Colorado (Scott liolmes)
Subject: Concrete Foundation Walls
Date: August 24, 1998 (1:00 pm) Weather: Warm
OBSERVATIONS
In general, the size, type and placement of the reinforcing steel is consistent with the structural
requirements outlined in the contract drawings. The horizontal reinforcement consists of No. 5,
Grade 40 steel, while the vertical dowels were No. 4, Grade 60 reinforcing bar. All reinforcement
was tied together properly, with taps at splices and comer bars being 24 inches in length.
FIELD INSTRUCTIONS GIVEN
cc:
F.
F. Plaza, P
PLAZA ENGINEERING CONSULTANTS, INC.
P.O. Box 1002 Loveland, CO 80539-1002 (970)-663-6353 (970) 663-0368 Fax
TOTAL P.01