Project: James Company Stanton Creek RU_D_, Filing 1 (Units 25-30)
Location: 6902 Antigua Drive, Fort Collins, Colorado.
Architect= Knudson Gloss Architects and Planners, Boulder, Colorado
Contractor. James Company, Boulder, Colorado (Scott Holmes)
Subject- Concrete Foundation Walls
Date: August 24, 1999 (1:00 pm) Weather: Warm
OBSERVATIONS
In general, the size, type and placement of the reinforcing steel is consistent with the structural
requirements oiat ined in the contract drawings. The horizontal reinforcement consists of No. 5,
Grade 40 steel, while the vertical dowels were No. 4, Grade 60 reinforcing bar. All reinforcement
was tied together properly, with laps at splices and corner bars being 24 inches in length.
FIELD RMSTRUCTIONS GIVEN
None.
Fiela
w..
�oF•P
F. Plaza, P,
cc: �F�i�1e
PLAZA ENGINEERING CONSULTANTS, INC.
P.O. Box 1002 Loveland, CO 80539-1002 (970)-663-6353 (970) 663-0368 Fax