Loading...
HomeMy WebLinkAbout444 PLOWMAN WAY - DISCLOSURES - 7/18/2002Sara's Energy Scoring 1225 w. Prospect P-14 DATE FT. COLLINS, CO 80526 07/18/02 (970)495-9603 CUSTOMER: Kaufman and Broad 444 Plowman Way Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 75 F Exterior Temp = 90 F Volume = 16147 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = .9 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 57 53 1307 1.3 Ring A 52 44 1192 —2.4 Ring A 45 39 1123 0.4 Ring A 36 30 986 0.8 Ring A 24 18 766 —0.1 Ring A 16 11 600 —0.2 Ring A Correlation Coefficient Flow Coefficient Exponent r = •9979 C = 113.69 n = 0.601 Results: Air Flow @ 50 Pascals : 1192 CFM50 +/— 0.8% 4.43 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 74.11 Square Inches +/— Equivalent Leakage Area (CANADA) = 133.11 Square Inches +/— Estimated Natural Infiltration (50 Pascal Flow Divided By 12.2) 98 CFM = 48.8 CFM/OCCUPANT = 0.36 AIR CHANGES PER HOUR 4.7% 2.9%