HomeMy WebLinkAbout6903 ANTIGUA PL - SPECIAL INSPECTIONS - 1/10/2002re
January 10, 2002
James Company
1133 Aruba Drive
Fort Collins, Colorado 80528
Attn: Mr. Greg Hinchy
Construction Superintendent @ Stanton Creek
Re: Foundation Excavation Observation
Lot 1, Block 2, Stanton Creek
6903 Antigua Place
Fort Collins, Colorado
Terracon Project No. 20015110
Mr. Hinchy:
Irerracon
301 N. Howes P.O. Box 503
Fort Collins, Colorado 80521-0503
(970)484-0359 Fax: (970) 484-0454
On December 11, 2001, a representative from Terracon observed the foundation excavation for
the referenced lot, as requested.
The soil conditions exposed within the upper foundation level consisted of sandy lean clay, and at
the lower foundation level claystone/bedrock was observed. These soil and/or bedrock conditions
are similar to those encountered in Earth Engineering Consultants Inc. (EEC) "Geotechnical
Engineering Report", project No. 1992129. Based on our observations, it is our opinion the
structure should be supported by a grade beam and straight shaft drilled pier/caisson foundation
system designed in accordance with the recommendations set forth in the EEC Geotechnical
Engineering Report.
At the time of the observation, no groundwater was encountered within two feet of the basement
foundation level. However, based on recommendations set forth in the EEC Geotechnical
Engineering Report, it is our opinion a dewatering system should be placed around the lower level
of the structure. The drainage system should be designed and constructed in accordance with the
recommendations set forth in the report.
rSinceO Revie
oskinson David
ICBO Inspector Geote
Copies to: (2) Addressee
� o
P
1 er, P.E.
cal Engineer/Department Manager
Arizona ■ Arkansas ■ Colorado ■ Georgia ■ Idaho ■ Illinois ■ Iowa ■ Kansas ■ Kentucky ■ Minnesota ■ Missouri ■ Montana
Nebraska ■ Nevada ■ New Mexico ■ Oklahoma ■ Tennessee ■ Texas ■ Utah ■ Wisconsin ■ Wyoming