HomeMy WebLinkAbout6903 ANTIGUA PL - SPECIAL INSPECTIONS - 1/18/2002 (2)January 18, 2002
James Company
1133 Aruba Drive
Fort Collins, Colorado 80528
Attn: Mr. Greg Hinchy
Construction Superintendent @ Stanton Creek
Re: Exterior Perimeter Drain Observation
Stanton Creek
6903 Antigua Place
Fort Collins, Colorado
Terracon Project No. 20015110
Mr. Hinchy:
QWM-*
Irerracon
301 N. Howes P.O. Box 503
Fort Collins, Colorado 80521-0503
(970)484-0359 Fax .(970)484-0454
A representative from Terracon observed the exterior perimeter drainage system at the
referenced address within the Sage Creek Development on January 7, 2002, as
requested. At the time of our site visit, a 4-inch diameter, perforated PVC pipe,
underlain by a PVC impervious liner material, had been placed around the exterior
perimeter of the basement foundation and was observed to exhibit positive gravity flow
toward a sump pit located in the lower level/basement portion of the residence. The
waterproof dampening of the foundation system was also observed and in our opinion
was completed in general accordance with standard residential practices.
In our opinion the exterior perimeter drainage system 1
accordance with the plans and specifications for the p .RE6/
0. .... s
Sinc ely, ��
TE C R�� y:
O
7ave nson David A. Richer,
Field Technician Geotechnical Enau
Copies to: Addressee (2)
in general
Manager