Loading...
HomeMy WebLinkAbout613 MEADOW RUN DR - SPECIAL INSPECTIONS - 9/12/199709/12/97 FRI 17:02 FAX 970 464 04D4 TERRACON 97Z3� 1 rerracon CONSULTANTS WESTERN, INC. SS I' G Cu 5 -7L) P0.Sox5a!•30tN.Howes Furl C IM C010Mdo 80522 (970) 454-0359 Fax: (970) 484-0464 September 12,1997 Classic Custom Homes 605 South College Avenue Fort Collins, Colorado 80524 RE: Chen Residence Lot 20 Meadow Run (ii2 Miramont Fort Collins, Colorado Project No. 20976099 Gentlemen: Larry G. O'Dell. P.E. Willem J. ANYMB. P.E. Nall R. Sharma, C.P.G. We have reviewed the garage door header sae and the columns beneath the roof beam at the comer of the master bedroom on the second floor and at the family room on the first floor as requested. Based on the imposed loads and the 16' span it is our opinion the garage door header may be (2)-1 314 x 140 LVL's instead of the W10 x 15 steel beam shown on the plan. The column at the master bedroom should be a TS 3 x 3 x 114 as shown on the plan, however the bottom plate may be a 5 x 5 x1/2 plate bearing on top of the LVL beam below. The column at the family room may be a 5-24 column instead of the TS 3 x 3 x 1l4 shown on the plan. The 5-24 column should be bolted together with two rows of 1/2 inch diameter bolts at 8' on center placed 1-1/2 inches from each edge. If you have any questions, please contact us. CONSULTANTS WESTERN, INC. /J a\�OQ�`q��REGI, Fy' Weeks, P.E o <<Q 0 Engineer 23012 ; = -P ; % 4J � '. ® 001 Offleos of Teo Torraeon Companfaa, kx.+, GaotaehNsal, Environmantni and Matorlala Enpinoaru Araces ❑ Arkanaes • Colorado Idaho ■ pbrota lb Iowa O Kansas ❑ k4nneswa ❑ Mlssoun Cl Montana ry Nebreaka • Nevada • Ndr� Dakola O Oklahoma Cl TenneSsae O Texas ❑ Utah O Wyoming DUALITY ENDMEERING SINCE 1955 • 0