HomeMy WebLinkAbout4315 GEMSTONE LN - DISCLOSURES - 12/22/1998May-07-95 07:55A Building and Zoning Dept. 970 224-6134 P.03
Jobaddress: 4315 Gemstone Lane, Ft'- Collins CO 80525
General contractor. Mark Twain Homes Inc.
Airseali'ngcontractor. Thermal Concepts
A Prescriptive path;:;. ...
Me certify that the air searing requirements specified in the current Cily of Fort Collins Residential Energy Code
have been completed in this building, in accordance with the "Air Sealing Checklist" published by the City of Fort Collins.
Certified by: Al Kulenski Phone: 970-223-7555
jBusinessfirm: Mark Twain Homes, Inc. Date: z0aa
zEL
Address: P.O. Box 270218 Ft. Collins Signature: G i %
80527
B ;Peiforrnance peEh
Me EerW that this building has met the air leakage performance threshold specified In the current
City of Fort Collins Residential Energy Code, in accordance with the "Slower Door Test Procedures," published
by the City of Fort Collins.
Testing contractor.
Date of i test:
CFM50:
Volume:
ACH50:
Certified by:
Business firm:
Address:
Air now through the blower door at 50 Pascals pressure difference Win)
Volume of home (cu. it)
Air change rate per hour at 50 Pascals pressure difference
ACH50 = (CFM50 x 60) / Volume
The performance threshold for code compliance Is ACH50
not exceeding 5.0 adh
Phone:
Date:
Signature:
Complete either Part A or Part B.
Part A is to be signed by the air sealing contractor or representative of the general contractor.
Part B Is to be signed by the blower door testing contractor or representative of the general contractor.
The "Blower Door Test Reporr or equivalent documentation must be attached.
Please type or print, except for the signature.
If components vary, make muttiplo entries to describe them.
One copy of this form shall be provided to the Building and Zoning Department at final inspection.
One copy of this form shall be provided to the homebuyer.
' "A.c."OtAilf — Vl4p
Fort Collins residential energy code 7/96
Insulation disclosure form
Address: 4315 Gemstone
ntractor: Mark Twain
lion Contractor: Thermal Concepts Insulation
P.O. Box 270066
Fort Collins, CO 80522
970-223-7090
£„j4�%��✓� � �.✓K;S#�N "'2 L s "Y6+'xU' R'e,4' ,me ��
Location
Material(s)
Thickness
Rated
R-value
Location
(Int/Ext)
Notes
Flat or vaulted ceilings with
attics above
Bloom Fiberglas
16"
38
19 bags-945 sq. f-
Ceilings with enclosed rafter
_Kraft_FG_batts_____-__
__-12_`_.
_flat_ c-eilings_
joists -to exterior
Frame walls and tiro/band
joists -to attik,gorage
. _batty ----
_6°
—_19___
l-ext"_Bmt.-J
Frame floor -cantilever _
r1(�i------------- ---
--
Fimne floor -over garage or
Crawl space
Slab -on -grade 10-1 T') -_� --
"
1g
- —batty ---
- --
- N/A _..--L ---
- --
-
Crawl space walls
N/A-- --
—
Basement walls
Vinyl faCe3 FIG b
t 3'�"
11
walls
_
FG-battS_—
_
Foam sealant
-FCm-rope_eXterlOL_
Caulk baseplates.
OOYs r- '
ani A
oam-mecbani
aals,
M
Cer#ificafion,
IPA"?''edify that the above listed insulation in the building of the above locations in conformonce with the�current requirements of the City of Fort Collins
P,,Ornnfinl Energy Code, and that it vms insfalled in nccordonce with the applicable "Insulation Installation Guidelines" published by the City of Fort Collins.
Certified by: Thermal Concepts Insulation Phone: 970-223-7090
Business firm: Thermal Concepts Insulation Date:
Address 6617 S. College Ave Signature --3
Instructions r a
Tbis disclosure for is to be signed by the insulation contractor or represenfafive of the general contractor.
Vln. �sn Type or print, except for the signature.
If • ,nnp� nerds "ry, make multiple entries to describe thorn.
Om, copy ofahis forte; shall he provided to the Building and Zoning Dapo, ln.ent of fmof impaUion.
Own only of 'll,is form shall be provided fo the home huger.
. — Fort Collins residential energy code 7196
_ Mechanical systems disclosure form
Job ade.--s=
General cent:..,: ter,
Mechanical Contract=
Space heating system .;:.
c.� a
___c_ coating system`;:..:
Water heating system
a -
Y input capacity `nergy � sicrage
-..csden Fuel Tvoe I Manufac-urer Mcde. - ketum cr kW Fac:ar ve:u.me
i I I I I I I
Me c3^( t�ai Se active-45ted eCUtcmeM`Nas :nsmiled in ttte tuacng =ttie above ICcaicns in ccniannanca with the
-e.;, fKUiremen5 at'U a Cat at Fart C-:fins Residential E-Iergy Cape and Hecianicat Cade, and that VNas insalted in
accz.--ance with manufacmrer's insauccns. Me cercfy that any aucrNarx has been installed in conformance with
the __pant;equiremena of t5e City of Par -Catlin Residential =.hers/ Coca and McC:anicai Cape.
Certified by, 3aoe77 `f'_ller Phone: 970-223-8V3
Business firm: tior_ e^_. Colorado Air, ZadDate:
Address: t823 Z. iia==7 Rd. Signature, 1,�le
�.
_ . ....._.. ..........................
.......... ......... ................ _ . _......................_................ _. .... ................_...._.. .
nsv"�c:ians ' . ::..:..
This c,dasure form is to be signed by the mechanical dantractar or representative of the general cpn==r.
Please type at print, except far the sigma m
If there are mutttoe systems serving anyfh:ndon, make multiple enties = describe them.
One ccf of this form shall be provided to me Building and Zoning Oepa=, ant atinai inspedon.
One copy of this form shall be provided to the homebuyer.��«_Kw