Loading...
HomeMy WebLinkAbout3230 GATLIN ST - SPECIAL INSPECTIONS - 7/9/1980MICKEY AND FOX, INC. CONSULTING ENGINEERS 3000 YOUNGFIELO ST. WHEAT RIDGE (DENVER%. COLORADO 9021S (303) 232.4977 FORREST R. MICKEY MICHAEL L. SCHNEIOER y July 9, 1980 Melody Homes 1719 Hull Street Fort Collins, Colorado 80526 3. Attention: Mr. Pat Clark Subject: Cantilever Floor Framing, Model 1116 Wagon Wheel Subdivision, Filing #2 Fort Collins, Colorado Mickey and Fox, Inc. Job No. 2.6146 Gentlemen: OFFICES: GRAND JUNCTION. COLORADO WHEAT RIDGE. COLORADO At the request of Mr. Pat Clark, we herewith enclose our calculations for the bedroom floor cantilevers of the subject residential model. The calculations are based on a 40 psf floor live load and a 30 psf roof snow load. Allowable stresses *ised are for Douglas Fir -Larch #2 and better framing lumber. The cantilever framing must support the roof bearing walls for Elevations "A-l" and "C" (trusses front to rear). As indicated in the calculations, 2 x 10 joists at 24" oc with 1 2 x 10 x 6' - 0" stiffener ("scab") nailed alongside every other joist is structurally adequate. If there are any questions or if we may be of further assistance, please call. Sincerely, MICKEY AND FOX, INC. Michael L. Schneider, PE MLS:slw enclosure 14360 a1v�F OF CGO O