HomeMy WebLinkAbout3002 DENVER DR - DISCLOSURES - 4/15/2014K } ,r' Date of Test: 4/15/2014 Customer: Journey Homes Greeley, CO 80634 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: BUILDING LEAKAGE TEST Test File: Journey Homes 3002 Denver BD Technician: Paul Higman Project Number: Building Address: 3002 Denver Fort Collins. CO 80525 1526 CFM50 (+/- 0.3 %) 3.67 ACH50 83.9 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 116.1 (+/- 2.4 %) Exponent (n) = 0.658 ( +/- 0.007 ) Correlation Coefficient = 0.99995 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 86.2 CFM 0.21 ACH 2. Estimated Design Infiltration Rate: Winter: 139.0 CFM Summer: 92.3 CFM 0.33 ACH 0.22 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed Paul by:,Faul Higman ,!DN: CN = Paul HigmanN"ianC=US ' -tDa e: 2014.04.17 t ; 1_ :43:02-06'00' No Text No Text No Text No Text