Loading...
HomeMy WebLinkAbout2263 Bar Harbor Dr - Disclosures/Blower Door Test - 12/09/2013Date of Test: 12/9/2013 Customer: Journey Homes LLC 7521 West 20th Street Suite L-200 Greeley, Colorado 80634 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: BUILDING LEAKAGE TEST Thermal Concepts 6617 South College Avenue Fort Collins, Colorado 80525 Test File: Journey Homes 2263 Bar Harbor Drive BD Technician: Project Number: Building Address: 1514 2263 Bar Harbor Drive Fort Collins, Colorado 805524 1135 CFM50 (+/- 0.6 %) 3.26 ACH50 62.4 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 80.5 (+/- 4.1 %) Exponent (n) = 0.676 ( +/- 0.011 ) Correlation Coefficient = 0.99986 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 12/9/2013 Test File: Journey Homes 2263 Bar Harbor Drive BD Building Information Location Climate Information Volume 20876 Ventilation Weather Factor 0.87 Surface Area Energy Climate Factor 17.00 FloorArea 2246 Heating Degree Days 6128 Height Cooling Degree Days 297 #of Bedrooms 3 Design Winter Wind Speed 7.3 mph #of Occupants Design Summer Wind Speed 9.4 mph Year of Construction 2013 Design Winter Temp Diff 73 deg F Wind Shield M Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency% Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 12/9/2013 Test File: Journey Homes 2263 Bar Harbor Drive BD Depressurization Test: Environmental Data Indoor Temperature(A°F) Outdoor Temperature (A°F) Altitude (ft) 80.0 2.0 4900.0 Data Points Nominal Baseiine Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -6.6 n/a n/a • -66.1 -59.1 62.1 1423 1278 0.5 Ring A -60.9 -54.0 53.6 1325 1190 -0.4 RingA -54.3 -47.3 44.9 1216 1092 -0.1 RingA -48.8 -41.8 37.7 1115 1001 -0.4 RingA �3.0 -36.0 30.6 1008 906 -0.3 RingA -36.7 -29.7 227.8 893 802 0.6 Ring B 30.7 -23.7 167.1 766 688 0.5 Ring B -24.5 -17.6 108.8 619 556 -0.5 Ring B -7.3 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test-Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12/9/2013 Test File: Journey Homes 2263 Bar Harbor Drive BD Comments House WRT Garage= -45.6 pa � ' �l�lJ � l 1 City of Fort Collins Planning, Development & Transportation Services /"`�f, Community Development& Neighborhood Services Simulated Performance Alternafive (SPA) Cover Sheet Submittal and Rating Type ❑Stock Plan Permit—Projected Worst-Case Rating Builder Model: ❑ Lot-specific Permit- Projected Rating Address: �Completed Home—Confirmed Rating Address: 2263 Bar Harbor Data Required for All SPA Ratings Builder: �ourney Homes Rating Firm: Thermal Concepts Paul Higman 12-9-13 Energy reter: Date: Duct Location In uts Location Su I Return % Area R-Value °/a Area R-Value Inside conditioned space 100 100 Utilit Rates Ener Source Service char e Rate Electricity 5 $/month D a9 $/kWh Natural gas 10 $/month o.65 $/therm , Spaces considered outside the thermal boundary: Additional Information for Stock Plan Permit— Projected Worst-Case Rating "Worst-case" configuration: Foundation type(s) Options included Orientation of front elevation ❑Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ❑Attach REM/Rate Energy Code Inspection Checklist Additional Information for Lot-Specific Permit— Projected Rating 0 Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ❑Attach REM/Rate Energy Code Inspection Checklist Additional Information for Completed Home — Confirmed Rating ❑Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report (Utility rates reflected in this report must be City-approved rates on lot-specific permit application date.) ❑Attach Home Energy Rating Certificate Updated 11/09/2012