HomeMy WebLinkAbout2263 Bar Harbor Dr - Disclosures/Blower Door Test - 12/09/2013Date of Test: 12/9/2013
Customer: Journey Homes LLC
7521 West 20th Street
Suite L-200
Greeley, Colorado 80634
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
BUILDING LEAKAGE TEST
Thermal Concepts
6617 South College Avenue
Fort Collins, Colorado 80525
Test File: Journey Homes 2263 Bar Harbor Drive BD
Technician:
Project Number:
Building Address: 1514
2263 Bar Harbor Drive
Fort Collins, Colorado 805524
1135 CFM50 (+/- 0.6 %)
3.26 ACH50
62.4 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 80.5 (+/- 4.1 %)
Exponent (n) = 0.676 ( +/- 0.011 )
Correlation Coefficient = 0.99986
4. Test Settings: Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
5. Accuracy Level Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate
2. Estimated Design Infiltration Rate:
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
BUILDING LEAKAGE TEST Page 2 of 4
Date of Test: 12/9/2013 Test File: Journey Homes 2263 Bar Harbor Drive BD
Building Information Location Climate Information
Volume 20876 Ventilation Weather Factor 0.87
Surface Area Energy Climate Factor 17.00
FloorArea 2246 Heating Degree Days 6128
Height Cooling Degree Days 297
#of Bedrooms 3 Design Winter Wind Speed 7.3 mph
#of Occupants Design Summer Wind Speed 9.4 mph
Year of Construction 2013 Design Winter Temp Diff 73 deg F
Wind Shield M Design Summer Temp Diff 15 deg F
Heating and Cooling Cost and Efficiency Information
Heating Fuel Gas
Heating Fuel Cost
Heating Efficiency%
Cooling Fuel Cost
Cooling SEER
Equipment Information
Type Manufacturer Model Serial Number Custom Calibration Date
Fan Energy Conservatory Model 3 (110V) Default
BUILDING LEAKAGE TEST Page 3 of 4
Date of Test: 12/9/2013 Test File: Journey Homes 2263 Bar Harbor Drive BD
Depressurization Test:
Environmental Data
Indoor Temperature(A°F) Outdoor Temperature (A°F) Altitude (ft)
80.0 2.0 4900.0
Data Points
Nominal Baseiine Adjusted Fan Nominal Adjusted
Building Pressure Building Pressure Pressure Flow Flow Fan
(Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration
-6.6 n/a n/a •
-66.1 -59.1 62.1 1423 1278 0.5 Ring A
-60.9 -54.0 53.6 1325 1190 -0.4 RingA
-54.3 -47.3 44.9 1216 1092 -0.1 RingA
-48.8 -41.8 37.7 1115 1001 -0.4 RingA
�3.0 -36.0 30.6 1008 906 -0.3 RingA
-36.7 -29.7 227.8 893 802 0.6 Ring B
30.7 -23.7 167.1 766 688 0.5 Ring B
-24.5 -17.6 108.8 619 556 -0.5 Ring B
-7.3 n/a n/a
Time Averaging Period: 0
Deviations from Standard RESNET Multi-Point Test-Test Parameters
None
BUILDING LEAKAGE TEST Page 4 of 4
Date of Test: 12/9/2013 Test File: Journey Homes 2263 Bar Harbor Drive BD
Comments
House WRT Garage= -45.6 pa
� ' �l�lJ � l 1
City of
Fort Collins Planning, Development & Transportation Services
/"`�f, Community Development& Neighborhood Services
Simulated Performance Alternafive (SPA) Cover Sheet
Submittal and Rating Type
❑Stock Plan Permit—Projected Worst-Case Rating Builder Model:
❑ Lot-specific Permit- Projected Rating Address:
�Completed Home—Confirmed Rating Address: 2263 Bar Harbor
Data Required for All SPA Ratings
Builder: �ourney Homes Rating Firm: Thermal Concepts
Paul Higman 12-9-13
Energy reter: Date:
Duct Location In uts
Location Su I Return
% Area R-Value °/a Area R-Value
Inside conditioned space 100 100
Utilit Rates
Ener Source Service char e Rate
Electricity 5 $/month D a9 $/kWh
Natural gas 10 $/month o.65 $/therm ,
Spaces considered outside the thermal boundary:
Additional Information for Stock Plan Permit— Projected Worst-Case Rating
"Worst-case" configuration:
Foundation type(s)
Options included
Orientation of front elevation
❑Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
❑Attach REM/Rate Energy Code Inspection Checklist
Additional Information for Lot-Specific Permit— Projected Rating
0 Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
❑Attach REM/Rate Energy Code Inspection Checklist
Additional Information for Completed Home — Confirmed Rating
❑Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
(Utility rates reflected in this report must be City-approved rates on lot-specific permit application date.)
❑Attach Home Energy Rating Certificate
Updated 11/09/2012