Loading...
HomeMy WebLinkAbout2014 WINAMAC DR - DISCLOSURES - 10/11/2013Date of Test: 10-11-13 Customer: Encore Homes Windsor. CO 80550 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College Ave Fort Collins, CO 80528 Test File: Encore Homes 2014 Winnimac-BD Technician: Paul Higman Project Number: Building Address: 2014 Winnimac Fort Collins, CO 80524 1063 CFM50 (+/- 0.8 %) 3.54 ACH50 0.6216 CFM50/ft2 floor area 53.3 in2 (+/- 4.4 %) Canadian EgLA @ 10 Pa 18.8in2(+/-6.9%)LBLELA@4Pa Flow Coefficient (C) = 14.4 ( +/- 10.8 %) Exponent (n) = 1.099 ( +/- 0.028 ) Correlation Coefficient = 0.99802 4. Test Settings: Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 18.6 CFM 0.06 ACH 2. Estimated Design Infiltration Rate: Winter: 31.7 CFM Summer: 17.8 CFM 0.11 ACH 0.06 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: No Text BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 10-11-13 Test File: Encore Homes 2014 Winnimac-BD Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) 70.0 55.0 Data Points -Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration 0.5 n/a n/a -58.8 -58.7 49.3 1272 1254 -1.1 Ring A -522 -52.1 38.0 1120 1104 -0.7 Ring A -47.0 -46.9 32.1 1031 1016 2.6 Ring A -41.6 -41.5 230.6 899 886 2.3 Ring B -37.4 -37.3 164.7 761 750 -2.6 Ring B -31.0 -30.9 116.9 642 633 1.0 Ring B -24.3 -24.2 64.7 479 472 -1.4 Ring B -19.7 -19.6 39.5 375 370 -2.7 Ring B -0.7 n/a n/a Deviations from Standard CGSB -Test Parameters - n value(1.099) outside of acceptable limits. . . _., BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 10-11-13 Test File: Encore Homes 2014 Winnimac-BD Comments House WRT Garage = -46.1pa