Loading...
HomeMy WebLinkAbout938 CAMPFIRE DR - DISCLOSURES - 9/12/2013BURGESS n� once 590" Uniform Energy Rating System 1 Star i 1 Star Plus 2 Stars 500401 I 400-301 300-251 HERS Index: 68 R" 2015 38 Campfire Drive Fort Collins, CO 80524 n 5 Stars Plus Confirmed Energy Efficient 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 250-201 200-151 V50-101 100-91 90-86 85-71 70 or Less Efficient Home Comparison: 32% Better General Information Conditioned Area: 3060 sq. ft. Conditioned Volume: 27039 cubic ft. Bedrooms: 4 HouseType: Single-family detached Foundation: Conditioned basement Mechanical Systems Features. - - - Registry ID: 397406865 Rating Number: Certified Energy Rater: Robert Hutchinson Rating Date: 9/11/2013 Rating Ordered For DR Horton Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 59.2 $411 24% Cooling 3.0 $80 5% Hot Water 21.5 $140 8% Lights/Appliances 32.8 $865 51% Photovoltaics -0.0 $-0 -0% Service Charges $204 12% Total 116.5 $1699 100% This home meets or exceeds the minimum criteria for all of the following: EPA ENERGY STAR Version 2 Home Heating: Fuel -fired air distribution, Natural gas, 92.0 AFUE 2006 International Energy Conservation Code Cooling: Air conditioner, Electric, 13.0 SEER. 2009 International Energy Conservation Code Water Heating: Conventional, Natural gas, 0.62 EF, 50.0 Gal. Duct Leakage to Outside: 0.00 CFM25. Ventilation System: Exhaust Only: 68 cfm, 11.3 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Building Shell Features Ceiling Flat: R-38 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: R-30 Vaulted Ceiling: NA Window Type: Double - Vinyl 3530""..... Above Grade Walls: R-15, R-19 Infiltration Rate: Htg: 1075 Clg: 1075 CFM50 Foundation Walls: R-19.0 Method: Blower door test - Lights and Appliance Features Percent Interior Lighting: 10.00 Range/Oven Fuel: Electric N,oa*cnrp � Burgess ConstructionConsultants Percent Garage Lighting:: 0.00 Clothes Dryer Fuel: Electric o 101 West Renner Road, Suite 400 *�o Refrigerator (kWh/yr): 775.00 Clothes Dryer EF: 2.67 Richardson, Texas 75082 Dishwasher Energy Factor: 0.68 Ceiling Fan (cfm/Watt): 0.00 214-888-7260 1, No. +esa-+44 e The Home Energy Rating Standard Disclosure for this home is available from the rating provider. 214-888-726 crp`O1P^O�p REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. 7479033 0 1985-2013 Architectural Energy Corporation, Boulder, Colorado. Certified Energy Rater Fort Collins Energy Cost Compliance - Non Electric Heat Property Organization DR Horton Burgesslnc. 938 Campfire Drive 303-300-4527 Fort Collins, CO 80524 Robert Hutchinson Weather:Ft. Collins, CO Builder 2015 DR Horton 938 Campfire Drive.blg Annual Energy Cost HERS Projected Rating 2/15/2013 RaterID:7470933 $/yr FC 2012 As Designed Heating 472 483 Cooling ill 100 Water Heating 139 139 SubTotal - Used to Determine;Compliance _ 72i 721 Lights Et Appliances 880 865 Photovoltaics -0 -0 Service Charge 204 204 �otal. --- . Y.0 79 Mandatory Requirements Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower) 0.400 0.340,. Home Infiltration (Section 402.4.2) PASSES Duct Leakage (Section 403.2.2) PASSES This home MEETS the annual energy cost requirements of Section 405 of the 20A9 International Energy Conservation Code, amended by the City of Fort Collins. Name Robert Hutchinson Signature bGG:�' �au6 6v-o Organization I Burgess Inc. Date 11 Se r 2013 Mechanical Systems Heating Cooling Water Heating Window -to -Floor Area Ratio: Blower door test Fuel -fired air distribution, 80.0 kBtuh, 92.0 AFUE. Air conditioner, 42.0 kBtuh, 13.0 SEER. Conventional, Gas, 0.62 EF. 0.15 Htg: 1075 Clg: 1075 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. o 1985-2013 Architectural Energy Corporation, Boulder, Colorado. Air `Leakage Property Organization HERS DR Horton Burgess Inc. Projected Rating 938 Campfire Drive 303-300-4527 2/15/2013 Fort Collins, CO 80524 Robert Hutchinson Rater ID:7470933 Weather:Ft. Collins, CO Builder 2015 DR Horton 938 Campfire Drive.blg Whole House Infiltration Blower Door Test Heating Cooling Natural ACH 0.15 0.11 ACH @ 50 Pascals 2.39 2.39 CFM @ 25 Pascals 685 685 CFM @ 50 Pascals 1075 1075 Eff. Leakage Area (sq.in) 59.0 59.0 Specific Leakage Area 0.00013 0.00013 ELA/100 sf shell (sq.in) 0.90 0.90 Duct Leakage Ventilation Leakage to Outside Units Hvac CFM @ 25 Pascals 0 CFM25 / CFMfan 0.0000 CFM25 / CFA 0.0000 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 0 Eff. Leakage Area (sgAn) 0.00 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0425 Mechanical Exhaust Only Sensible Recovery Eff. (%) 0.0 Total Recovery Eff. (%) 0.0 Rate (cfm) 68 Hours/Day 24.0 Fan Watts 11.3 Cooling Ventilation Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings, a minimum of 68 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 136 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required . REM/Rate -Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. o 1985-2013 Architectural Energy Corporation, Boulder, Colorado. CO WRL"(MON xisxaeu. 2005 EPACT ENERGY EFFICIENT HOME TAX CREDIT ( 13-001 ) Date: September 12, 2013 Rating No.: Building Name: 2015 Rating Org.: Burgess Inc. Owner's Name: DR Horton Phone No.: 303-300-4527 Property: 938 Campfire Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO 80524 Rater's No.: 7479033 Builder's Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 938 Campfire Drive.blg Rating Date: 9/11/2013 Normalized, Modified End -Use Loads (MMBtu/year) Envelope Loads (MMBtu/year) 2006 IECC 2006 IECC 50% Target As Designed _ 90% Target As Designed Heating: 30.7 34.0 Heating: 55.3 54.1 Cooling: 6.7 8.8 Cooling: 12.1 10.7 Total: 37.4 42.9 Total: 67.4 64.9 This home DOES NOT meet the requirements for the residential energy efficiency tax credits under Section 1332, Credit for Construction of New Energy Efficient Homes, of the Energy Policy Act of 2005 extended to December 31, 2013. Ceiling Flat: R-38 Sealed Attic: NA Vaulted Ceiling: NA Above Grade Walls: R-15, R-19 Foundation Walls: R-19.0 Exposed Floor: R-30 Building Features Slab: R-0.0 Edge, R-0.0 Under Duct: Uninsulated Window: U-Value: 0.340, SHGC: 0.300 Heating Fuel -fired air distribution, Natural gas, 92.0 AFUE. Cooling Air conditioner, Electric, 13.0 SEER. Under penalties of perjury, I declare that I have examined this certification, including accompanying documents, and to the best of my knowledge and belief, the facts presented in support of this certification are true, correct, and complete. Name: Robert Hutchinson Signature: Company: Burgess Inc. Date: September 12, 2013 Address: 9033 E. Easter Place, Ste. 200, Centennial, CO 80112 REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. ©1985-2013 Architectural Energy Corporation, Boulder, Colorado. BURGESS Im I i�"I�A�MIRL' T!nv 2009 IECC ANNUAL ENERGY COST COMPLIANCE Date: September 12, 2013 Rating No.: Building Name: 2015 Rating Org.: Burgess Inc. Owner's Name: DR Horton Phone No.: 303-300-4527 Property: 938 Campfire Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO 80524 Rater's No.: 7479033 Builder's Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 938 Campfire Drive.blg Rating Date: 9/11/2013 Annual Energy Cost($) 2009 IECC As Designed Heating: 575 483 Cooling: 87 100 Water Heating: 139 139 SubTotal - Used to Determine Compliance: 801 721 Lights & Appliances: 880 865 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1885 1790 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.340 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the re . ments by 9.9%. Name: Robert Hutchinson Signature: 7479033 Organization: Burgess Inc. Date: Seer 12, 2013 " Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 80.0 kBtuh, 92.0 AFUE. Cooling: Air conditioner, 42.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.62 EF. Window -to -Floor Area Ratio: 0.15 REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. 01986-2013 Architectural Energy Corporation, Boulder, Colorado. 2015 2009 IECC ANNUAL ENERGY COST COMPLIANCE Page 2 Blower door test: Htg: 1075 Clg: 1075 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. ©1985-2013 Architectural Energy Corporation, Boulder, Colorado. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 938 Campfire Drive, Fort Collins, CO by DR Horton exceeds the minimum requirements for the 2009 International Energy Conservation Code Ceiling Flat: R-38 Sealed Attic: NA Vaulted Ceiling: NA Above Grade Walls: R-15, R-19 Foundation Walls: R-19.0 Exposed Floor: R-30 Slab: R-0.0 Edge, R-0.0 Under Duct: NA 9/11/2013 Building Features Duct Leakage to Outside: 0.00 CFM @ 25 Pascals Total Duct Leakage: 130.00 CFM @ 25 Pascals Infiltration: Htg: 1075 Clg: 1075 CFM50 Window: U-Value: 0.340, SHGC: 0.300 Heating Fuel -fired air distribution, Natural gas, 92.0 AFUE. Cooling Air conditioner, Electric, 13.0 SEER. Water Heating Conventional, Natural gas, 0.62 EF, 50.0 Gal. The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in compliance with Chapter 4 based on Climate Zone 5B and with all mandatory requirements. Name: Robert Hutchinson Signature: i_" 7479033 Organization: Burgess Inc. Date: Seer 12, 2013 The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC'9. No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Enerav Analvsis and Ratin4 Software v14.3 2009 IECC Certificate 938 Campfire Drive, Fort Collins, CO 80524 Building Envelope Insulation Ceiling Flat: R-38 Vaulted Ceiling: NA Above Grade Walls: R-15, R-19 Foundation Walls: R-19.0 Exposed Floor: R-30 Slab: R-0.0 Edge, R-0.0 Under Infiltration: Htg: 1075 Clg: 1075 CFM50 Duct NA Duct Leakage to Outside: 0,00 CFM @ 25 Pascals Window Data U-Factor SHGC Window: 0,340 0.300 Mechanical Equipment HEAT: Fuel -fired air distribution, Natural gas, 92.0 AFUE. COOL: Air conditioner, Electric, 13.0 SEER. DHW: Conventional, Natural gas, 0.62 EF, 50.0 Gal. Builder or Design Professional Signature REM/Rafe - Residential Energy Analysis and Rating Software v14.3 (oW RGCTIOS l (iAA I:I� 1A' IS Estimated Annual Energy Cost $1yr 2000 1500 1000 500 410 5 0 1 � m c 864.9 I 801 139.5 a m on Q °o a1pi ro U 2 1699.0 i I i 2040 U_ 1D i U t a m HOME PERFORMANCE ENERGY RATING CERTIFICATE HERS® Index More Energy 150 140 Existing 130 Homes 120 110 Standard 100 New Home 90 80 This Hdme it 70 sg 60 — — —I 50�� 40 __-- 30 20 Zero Energy 10 Home 0 Less Energy Estimated Annual Energy Consumption MMBtu/yr 140 r 120 116.5 100 80 59,2 60 40 32.8 21.5 20 0 `m `m 2 $ 2 w o m `o 3 Name: 2015 Annual .Estimates': Address: 938 Campfire Drive Electric(kWh): 10897 Burgess ConstructionConsultants Inc Fort Collins, CO 60524 Natural gas(Therms): 793 101 West Renner Road, Suite 400 House Type Single-family detached CO2 emissions(Tons): 14 Certified Rater: Robert Hutchinson Cond. Area: 3060 sq. ft. Annual Savings": $1001 Rater ID: 7479033 .p Rating NO.: T No. 1998-144, Registry ID: 397406855 m Issue Date: September 12, 2013 *Based on standard operating conditions Rating Date: 9/11/2013 Certification. Verified "Based on a HERS 1301ndex Home Signature: d,4Z 7479033 REWRate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. ® 1985-2013 Architectural Energy Corporation, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. BURGESS leIiCe11� 3,2 FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: September 12, 2013 Rating No.: Building Name: 2015 Rating Org.: Burgess Inc. Owner's Name: DR Horton Phone No.: 303-300-4527 Property: 938 Campfire Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO 80524 Rater's No.: 7479033 Builders Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 938 Campfire Drive.blg Rating Date: 9/11/2013 Annual Energy Cost ($) FC 2012 As Designed Heating: 472 483 Cooling: 111 100 Water Heating: 139 139 SubTotal - Used to Determine Compliance: 721 721 Lights & Appliances: 880 865 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1805 1790 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.340 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins4_� Name: Robert Hutchinson Signature: _747903 Organization: Burgess Inc. Date.. September 12, 2013 Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 80.0 kBtuh, 92.0 AFUE. Cooling: Air conditioner, 42.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.62 EF. Window -to -Floor Area Ratio: 0.15 REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. 01985-2013 Architectural Energy Corporation, Boulder, Colorado. ✓t) FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT 2015 Page 2 Blower door test: Htg: 1075 Clg: 1075 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. ©1985-2013 Architectural Energy Corporation, Boulder, Colorado.