HomeMy WebLinkAbout2303 SUNBURY LN - DISCLOSURES - 9/6/2013 (21)Date of Test: 9-6-13 Customer: Journey Homes Greeley, CO 80634 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: 4. Test Settings: BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Test File: Journey Homes 2303 Sunbury BD Technician: Paul Higman Project Number: Building Address: 2303 Sunbury Fort Collins, CO 80524 1272 CFM50 (+/- 1.0 %) 3.43 ACH50 0.4856 CFM50/ft2 floor area 195.9 in2 (+/- 3.5 %) Canadian EgLA @ 10 Pa 131.0in2(+/-5.7%)LBLELA@4Pa Flow Coefficient (C) = 264.5 ( +/- 9.1 %) Exponent (n) = 0.401 ( +/- 0.024 ) Correlation Coefficient = 0.98733 Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 109.2 CFM 0.29 ACH 2. Estimated Design Infiltration Rate: Winter: 165.7 CFM Summer: 97.8 CFM 0.45 ACH 0.26 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 9-6-13 Test File: Journey Homes 2303 Sunbury BD Building Information Location Climate Information Volume 22270 Ventilation Weather Factor 0.87 Surface Area Energy Climate Factor 17.00 FloorArea 2620 Heating Degree Days 6020 Height 9 Cooling Degree Days 287 #of Bedrooms 3 Design Winter Wind Speed 9.0 mph #of Occupants Design Summer Wind Speed 7.0 mph Year of Construction 2013 Design Winter Temp Diff 69 deg F Wind Shield M Design SummerTemp Diff 16 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 1 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 9-6-13 Test File: Journey Homes 2303 Sunbury BD Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) 79.0 89.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) °/a Error Configuration -0.9 n/a n/a -60.2 -59.2 59.4 1393 1406 3.3 RingA -55.2 -54.2 51.7 1302 1314 0.0 Ring A -50.1 -49.1 47.0 1242 1253 -0.7 Ring A -45.2 -44.2 42.2 1179 1190 -1.7 Ring A -40.5 -39.5 36.7 1101 1111 -4.0 RingA -35.5 -34.5 35.0 1076 1086 -0.9 RingA -30.2 -29.2 31.0 1015 1024 -0.1 RingA -25.2 -24.2 27.3 954 963 1.3 RingA -20.4 -19.4 224.4 887 895 2.9 Ring B -1.1 n/a n/a Deviations from Standard CGSB-Test Parameters - n value (0.401) outside of acceptable limits. - Correlation coefficient(0.987) outside of acceptable limits. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 9-6-13 Test File: Journey Homes 2303 Sunbury BD Comments House wrt Garage = -47.2pa