Loading...
HomeMy WebLinkAbout2251 SUNBURY LN - DISCLOSURES - 9/5/2013 (10)Date of Test: 9-5-13 Customer: Journey Homes Greeley, CO 80634 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: 4. Test Settings: BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Test File: Journey Homes 2251 Sunbury BD Technician: Paul Higman Project Number: Building Address: 2251 Sunbury Ln Fort Collins, CO 80524 1282 CFM50 (+/- 0.6 %) 3.69 ACH50 0.5710 CFM50/ft2 floor area 157.4 in2 ( +/- 2.2 %) Canadian EgLA @ 10 Pa 92.5 in2 (+/- 3.6 %) LBL ELA @ 4 Pa Flow Coefficient (C) = 153.8 ( +/- 5.6 %) Exponent (n) = 0.542 ( +/- 0.015 ) Correlation Coefficient = 0.99731 Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 95.0 CFM 0.27 ACH 2. Estimated Design Infiltration Rate: Winter: 156.2 CFM Summer: 87.7 CFM 0.45 ACH 0.25 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 9-5-13 Test File: Journey Homes 2251 Sunbury BD Building Information Location Climate Information Volume 20876 Ventilation Weather Factor 0.87 Surface Area Energy Climate Factor 17.00 FloorArea 2246 Heating Degree Days 6020 Height 18 Cooling Degree Days 287 #of Bedrooms 3 Design Winter Wind Speed 9.0 mph #of Occupants Design Summer Wind Speed 7.0 mph Year of Construction 2013 Design Winter Temp Diff 69 deg F Wind Shield M Design Summer Temp Diff 16 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 9-5-13 Test File: Journey Homes 2251 Sunbury BD Depressurization Test: Environmental Data Indoor Tempereture (°F) Outdoor Temperature (°F) 76.0 91.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.0 n/a n/a -60.0 -59.0 58.7 1385 1404 0.1 RingA -55.0 -54.0 53.6 1325 1343 0.5 RingA -50.4 -49.4 48.7 1264 1282 0.6 RingA -45.0 -44.0 42.4 1182 1198 0.2 RingA -40.5 -39.5 37.5 1113 1128 -0.0 RingA -35.0 -34.0 30.0 999 1013 -2.6 Ring A -30.4 -29.4 249.6 935 948 -1.4 Ring B -25.1 -24.1 204.0 846 858 -0.6 Ring B -20.1 -19.1 172.2 778 789 3.6 Ring B -1.0 n/a n/a Deviations from Standard CGSB-Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 9-5-13 Test File: Journey Homes 2251 Sunbury BD Comments House wrt Garage = -47.1 pa