Loading...
HomeMy WebLinkAbout415 NOQUET CT - DISCLOSURES - 6/6/2013/►+�� Registry ID: Rating Number: Certified Energy Rater: Paul Higman Rating Date: 6-6-13 415 Noquet Ct Rating Ordered For: Encore Homes Fort Collins, CO 80524 5 Stars Plus Confirmed Rating Uniform Energy Rating System Energy Efficient 1 Star 1 Star Plus 2 Stars 12 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 15 Stars Plus 500-401 I_400-301_ 300-251_ _ 250-201 200=151 _ 150-101 `100-91 90-86 85-71 70 or Less HERS Index: 63 General Information Conditioned Area: 2288 sq. ft. Conditioned Volume: 16392 cubic ft. Bedrooms: 3 Mechanical Systems Features Heating: Cooling: Water Heating: Duct Leakage to Outside: Ventilation System: Programmable Thermostat: Building Shell Features Ceiling Flat: Vaulted Ceiling: Above Grade Walls: Foundation Walls: 101101 HouseType: Single-family detached Foundation: Conditioned crawl space Fuel -fired air distribution, Natural gas, 95.OAFUE. Air conditioner, Electric, 13.0 SEER. Conventional, Electric, 0.95 EF, 40.0 Gal. 38.00 CFM. Exhaust Only: 57 cfm, 24.0 watts. Heating: Yes Cooling: Yes R-38 Exposed Floor: NA Window Type: R-19 Infiltration: R-38 U.0.33,SHGCO.31 R-19.0 Rate: Htg: 1045 Clg: 1045 CFM50 None Method: Blower door test Estimated Annual Energy Cost Confirmed Rating Use MMBtu Cost Percent Heating 35.9 $249 16% Cooling 2.5 $66 4% Hot Water 13.3 $352 22% Lights/Appliances 26.4 $695 44% Photovoltaics -0.0 $-0 -0% Service Charges $204 13% Total $1566 100% This home meets or exceeds the minimum criteria for all of the following: 2006 International Energy Conservation Code 2009 International Energy Conservation Code City of Fort Collins Green Code 2012` Compliance with criteria for this program is determined by the rater. Lights and Appliance Features Digitally signed Percent Interior Lighting: 0.00 Range/Oven Fuel: Electric Masco Home Services Paul by: Paul Higman RCN Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric 2339 Beville Rd DN = Paul Refrigerator (kWhtyr): 575.00 Clothes Dryer EF: 3.01 Daytona Beach, FL. 32119 1 Higman C = US Dishwasher Energy Factor: 0.64 Ceiling Fan (cfm=att): 0.00 3860-304-2200 Higman, ate: 2013.06. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. - ' 07"08:26:03 - REM/Rate - Residential Energy Analysis and Rating Software v12.97 06 00 This information does not constitute any warranty of energy cost or savings. © 1985-2012 Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: June 07, 2013 Rating No.: Building Name: 415 Noquet Ct Rating Org.: Thermal Concepts Owner's Name: Encore Homes Phone No.: 970-223-7090 Property: 415 Noquet Ct Raters Name: Paul Higman Address: Fort Collins, CO 80524 Rater's No.: 6784592 Builder's Name: Encore Homes LLC Weather Site: Ft. Collins, CO Rating Type: Confirmed Rating File Name: Encore Homes 415 Noquet-Remington-final.blg Rating Date: 6-6-13 Annual Energy Cost ($) FC 2012 As Designed Heating: - 334 292 . Cooling: 88 80 Water Heating: 352 352 SubTotal - Used to Determine Compliance: 773 724 Lights &Appliances: 709 709 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1686 1637 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.334 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 6.4%. Name: Paul Higman Signature: Organization: Thermal Concepts Date: June 07, 2013 -- - Digitally signed by:.Paul Pau[ Design energy cost is based on the following systems: Higman Heating: Fuel -fired air distribution, 64.0 kBtuh, 95.0 AFUE. DN:;CN = Paul Higman C = Cooling: Air conditioner, 24.0 kBtuh, 13.0 SEER. Higman USI Water Heating: Conventional, Elec, 0.95 EF ,;'Date: 2013.06.07 08:25:38 - Window -to -Floor Area Ratio:0.10 06'00' Blower door test: Htg: 1045 Clg: 1045 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. © 1985-2012 Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT 415 Noquet Ct Page 2 equal to those in the design home as specified in the 2009 IECC. These standards are subjectto change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate -Residential Energy Analysis and Rating Software 02.97 This information does not constitute any warranty of energy cost or savings. ©1985-2012Architectural Energy Corporation, Boulder, Colorado.