HomeMy WebLinkAbout427 TORONTO ST - DISCLOSURES - 6/20/2013i g OaO Ce BUILDING LEAKAGE TEST .x 1. /IASC Contractor Services Date of Test: 6/20/2013 Customer: Encore Homes Windsor, CO 80550 Test File: Encore Homes 427 Toronto Garfeild BD report Technician: Paul Higman Project Number: Building Address: Garfield 427 Toronto Fort Collins, CO 80524 Test Results 1. Airflow at 50 Pascals: 1127 CFM50 (+/- 6.8 %) (50 Pa = 0.2 w.c.) 3.72 ACH50 2. Leakage Area: 62.0 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 86.0 (+/- 53.9 %) Exponent (n) = 0.658 ( +/- 0.148 ) Correlation Coefficient = 0.97562 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 63.7 CFM 0.21 ACH 2. Estimated Design Infiltration Rate: Winter: 102.7 CFM Summer: 68.2 CFM 0.34 ACH 0.22 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating 2. Estimated Cost of Air Leakage for Cooling t�5co BUILDING LEAKAGE TEST Page 2 of 4 Cnntractar r"=-J Services Date of Test: 6/2012013 Test File: Encore Homes 427 Toronto Garfeild BD report Building Information Volume 18207 Surface Area Floor Area 1585 Height 18 # of Bedrooms 3 # of Occupants Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 29318-7 12/29/2010 .mksco BUILDING LEAKAGE TEST Page 3 of 4 Contractor Services Date of Test: 6/20/2013 Test File: Encore Homes 427 Toronto Garfeild BD report Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (OF) Altitude (ft) 83.0 I 85.0 4900.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -5.4 n/a n/a -63.4 -60.1 44.1 -58.1 -54.8 42.2 -51.2 -48.0 35.1 -47.2 -44.0 28.5 -40.9 -37.6 25.3 -33.1 -29.8 131.1 -28.2 -24.9 152.3 -23.8 -20.6 105.4 -1.0 n/a n/a Time Averaging Period: 0 1205 1257 -1.2 Ring A 1179 1230 2.7 Ring A 1077 1124 2.4 Ring A 974 1016 -1.9 Ring A 919 958 2.5 Ring A 680 709 -11.7 Ring B 732 764 7.1 Ring B 610 636 1.2 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters None * correlation coefficient outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi -Point Test Standard. .NtkK0 BUILDING LEAKAGE TEST Page 4 of 4 lt Contractor==" L,=�L, Services Date of Test: 6/20/2013 Test File: Encore Homes 427 Toronto Garfeild BD report Comments House WRT Garage =-45.2pa correction coefficient is low because of windy conditions