HomeMy WebLinkAbout439 HOUGHTON CT - DISCLOSURES - 8/21/2013 (3)FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
Date: August 21,2013
Rating No.:
Building Name: 439 Houghton
Rating Org.:
Thermal Concepts
Owner's Name: Encore Homes
Phone No.:
970-223-7090
Property: 439 Houghton
Rater's Name:
Paul Higman
Address: Fort Collins, CO 80524
Rater's No.:
6784592
Builder's Name: Encore Homes LLC
Weather Site: Ft Collins, CO
Rating Type:
Confirmed Rating
File Name: Encore Homes 439 Houghton -Remington-final.b
Rating Date:
8-21-13
Annual Energy Cost ($)
FC 2012 As Designed
Heating:
334
302
Cooling:
88
79
Water Heating:
352
352
SubTotal - Used to Determine Compliance:
774
733
Lights &Appliances:
709
709
Photovoltaics:
-0
-0
Service Charge:
204
204
Total:
1687
1645 '
Window U-Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower): 0.400 0.334
Home Infiltration (Section 402.4.2): PASSES
Duct Leakage (Section 403.2.2): PASSES
This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy
Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 5.3%.
Name: Paul Higman Signature:
Organization: Thermal Concepts Date: August21,2013
Paul Digitally-signed-by=P-*.Paul
' Design energy cost is based on the following systems: Higman
Heating: Fuel -fired air distribution, 64.0 kBtuh, 95.OAFUE. DN:(CN = Paul Higman C = US
Cooling: Air conditioner, 24.0 kBtuh, 13.0 SEER. Higman Date: 2013.08.21 14:27:01 -
Water Heating: Conventional, Elec, 0.95 EF. Z 06;00'
Window -to -Floor Area Ratio: 0.10 /
Blower door test: Htg: 1027 Clg: 1027 CFM50
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been
changed
prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies
are set
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
O 1985-2012 Architectural Energy Corporation, Boulder, Colorado.
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
439 Houghton
Page 2
equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and
software
updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum
standards.
REM/Rate -Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
0 1985-2012Architectural Energy Corporation, Boulder, Colorado.
439 Houghton
Fort Collins, CO 80524
*=Lnr-j
5 Stars Plus
Confirmed Rating
Uniform Energy Rating System Energy Efficient
1 Star I 1 Star Plus Stars 4 Stars Plu 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 s 5 Stars 5 Stars Plus
500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less
HERS Index: 64
General Information
Conditioned Area: 2288 sq. ft. HouseType: Single-family detached
Conditioned Volume: 16392 cubic ft. Foundation: Conditioned crawl space
Bedrooms: 3
Mechanical Systems Features i
Heating: Fuel -fired air distribution, Natural gas, 95.OAFUE.
Cooling: Air conditioner, Electric, 13.0 SEER.
Water Heating:. Conventional, Electric, 0.95 EF, 40.0 Gal.
Duct Leakage to Outside: 27.00 CFM.
Ventilation System: Exhaust Only: 72 cfm, 24.0 watts.
Programmable Thermostat: Heating: Yes Cooling: Yes
Building Shell Features
Ceiling Flat: R-38 Exposed Floor: R-38
Vaulted Ceiling: NA Window Type: U.0.33,SHGCO.31
Above Grade Walls: R-19 Infiltration:
Foundation Walls: R-19.0 Rate: Htg: 1027 Clg: 1027 CFM50
Slab: None Method: Blower door test
Llghts and Appliance Features
Percent Interior Lighting: 0.00 Range/Oven Fuel: Electric
Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric
Refrigerator (kWh/yr): 575.00 Clothes Dryer EF: 3.01
Dishwasher Energy Factor: 0.64 Ceiling Fan (cfmANatt): 0.00
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
0 1985-2012Architectural Energy Corporation, Boulder, Colorado.
Registry ID:
Rating Number:
Certified Energy Rater: Paul Higman
Rating Date: 8-21-13
Rating Ordered For: Encore Homes
Estimated Annual Energy Cost
.Confirmed Rating
Use MMBtu Cost Percent
Heating 37.2 $258 16%
Cooling 2.5 $65 4%
Hot Water 13.3 $352 22%
Lights/Appliances 26.4 $695 44%
Photovoltaics -0.0 $-0 -0%
Service Charges $204 13%
Total $1574 100%
This home meets or exceeds the minimum
criteria for all of the following:
2006 International Energy Conservation Code
2009 International Energy Conservation Code
City of Fort Collins Green Code 2012'
` Compliance with criteria for this program is
determined by the rater.
Digitally signed
Masco Home Services Pau I by- Paul Higman
2339 Beville Rd DIV: CN = Paul
Daytona Beach, FL. 32119 Higman C = US
3860-304-2200 H i g m a nbate: 2013.08.
21J14:27:22 -
06'00'