Loading...
HomeMy WebLinkAbout439 HOUGHTON CT - DISCLOSURES - 8/21/2013 (4)C Date of Test: 8-21-13 Customer: Encore Homes Windsor, CO 80550 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College Ave Fort Collins, CO 80525 Test File: Encore Homes 439 Houghton BD Technician: Paul Higman Project Number: Building Address: 439 Houghton Fort Collins, CO 80524 1027 CFM50 (+/- 1.0 %) 3.74 ACH50 0.6543 CFM50/ft2 floor area 74.2 in2 (+/- 4.3 %) Canadian EgLA @ 10 Pa 32.3 in2 (+/-7.0 %) LBLELA@4 Pa Flow Coefficient (C) = 34.0 ( +/- 11.2 %) Exponent (n) = 0.871 ( +/- 0.030 ) Correlation Coefficient = 0.99644 4. Test Settings: Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 32.0 CFM 0.12 ACH 2. Estimated Design Infiltration Rate: Winter: 54.5 CFM 0.20 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Summer: 30.6 CFM 0.11 ACH BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 8-21-13 Test File: Encore Homes 439 Houghton BD Building Information Location Climate Information Volume 16474 Surface Area Floor Area 1569 Height 16 # of Bedrooms 3 # of Occupants Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6020 Cooling Degree Days 287 Design Winter Wind Speed 9.0 mph Design Summer Wind Speed 7.0 mph Design Winter Temp Diff 69 deg F Design Summer Temp Diff 16 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 8-21-13 Test File: Encore Homes 439 Houghton BD Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) 72.0 82.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -1.3 n/a n/a -55.2 -53.8 34.1 -50.2 -48.8 29.4 -45.1 -43.7 242.6 40.7 -39.3 201.6 -35.6 -34.2 157.8 -30.1 -28.7 113.2 -25.2 -23.8 77.6 -20.5 -19.1 48.5 -1.5 n/a n/a None Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 1062 1072 -2.0 Ring A 989 998 -0.7 Ring A 922 931 1.9 Ring B 841 849 2.0 Ring B 745 752 2.0 Ring B 632 638 0.8 Ring B 524 529 -1.6 Ring B 415 419 -5.6 Ring B Deviations from Standard CGSB - Test Parameters BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 8-21-13 Test File: Encore Homes 439 Houghton BD Comments House wrt Garage =-46.8pa t,�0 13` t City of Fort Cottins Planning, Development & Transportation Services µ' `�000 ` Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet Submittal and Rating Type ❑ Stock Plan Permit — Projected Worst -Case Rating Builder Model: I Remington ❑ Lot -specific Permit - Projected Rating Address: Completed Home — Confirmed Rating Address: 439 Houghton Data Required for All SPA Ratings Builder: Encore Homes Rating Firm: Thermal Concepts Paul Higman 8-21-13 Energy rater: Date: Duct Location Inputs Location Su ply Return % Area R-Value % Area R-Value Inside conditioned space 100 100 Utility Rates Energy Source Service charge Rate Electricity 5 $/month 0.09 $/kWh Natural gas 10 $/month 0.65 $/therm Spaces considered outside the thermal boundary: Additional Information for Stock Plan Permit — Projected Worst -Case Rating "Worst -case" configuration: Foundation Options included Orientation of front elevation ❑ Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ❑ Attach REM/Rate Energy Code Inspection Checklist Additional Information for Lot -Specific Permit — Projected Rating ❑ Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ❑ Attach REM/Rate Energy Code Inspection Checklist Additional Information for Completed Home — Confirmed Rating ❑ Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report (Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.) ❑ Attach Home Energy Rating Certificate Updated 11/09/2012