HomeMy WebLinkAbout2512 BANBURY LN - DISCLOSURES - 8/13/2013BUILDING LEAKAGE TEST
Date of Test: 8/13/2013
Customer: Journey Homes
Greeley, CO 80634
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
Test File: Journey Homes 2512 BranburyBD
Technician:
Project Number:
Building Address: 2512 Banbury Lane
Fort Collins, CO 80524
1351 CFM50 (+/- 1.6 %)
3.61 ACH50
74.3 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 67.4 (+/- 11.5 %)
Exponent (n) = 0.766 ( +/- 0.032 )
Correlation Coefficient = 0.99914
4. Test Settings: Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
5. Accuracy Level Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate: 76.4 CFM
0.20 ACH
2. Estimated Design Infiltration Rate:
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
Winter: 123.1 CFM Summer: 81.7 CFM
0.33 ACH 0.22 ACH
BUILDING LEAKAGE TEST Page 2 of 4
Date of Test: 8/13/2013 Test File: Journey Homes 2512 BranburyBD
Building Information Location Climate Information
Volume
22477
Surface Area
Floor Area
2413
Height
18
# of Bedrooms
3
# of Occupants
Year of Construction
2013
Wind Shield
M
Heating and Cooling Cost and Efficiency Information
Heating Fuel Gas
Heating Fuel Cost
Heating Efficiency %
Cooling Fuel Cost
Cooling SEER
Ventilation Weather Factor
0.87
Energy Climate Factor
17.00
Heating Degree Days
6128
Cooling Degree Days
297
Design Winter Wind Speed
7.3 mph
Design Summer Wind Speed
9.4 mph
Design Winter Temp Diff
73 deg F
Design Summer Temp Diff
15 deg F
Equipment Information
Type
Manufacturer
Model
Serial Number
Custom Calibration Date
Fan
Energy Conservatory
Model 3 (110V)
Default
Micromanometer
Energy Conservatory
DG700
29318-7
No Text
No Text