HomeMy WebLinkAbout874 CAMPFIRE DR - APPLICATIONS - 6/26/2013/� 3 y_ y
City of I COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES
For t Collins 281 N. College Ave. • Fort Collins, CO 80524 • Phone: 970-416-2740
www.fcgov.com/building
BUILDING PERMIT APPLICATION !—
APPLICATION NUMBER � � B �+� APPLICATION DATE `°' •�- 13
Job Site Address
Unit # N/A
PROPERTY OWNER INFO: (All owner information is required - it is not optional) Phone # 303-488-0061
Last name D. R. HORTON, INC- First Name Middle
Street Address 9555 S. KINGSTON CT., SUITE 200 City ENGLEWOOD State CO Zip 80112
CONTRACTOR INFO: Company Name D. R. HORTON, INC. Contractor Phone It 303-488-0061
Lic Holder Name JOSHUA VICARS City of Fort Collins License # D-590 Supervisor Cent # 3035-D1
Mailing Address 9555 S. KINGSTON CT., SUITE 200 City ENGLEWOOD State CO Zip 80112
LEGAL INFO:
Subdivision/PUD Filing# Lot #
TRAIL HEAD N/A �
Block # Lot Sq Ft
CONSTRUCTION INFO: Total Building Sq Ft (notinduding basement) �a5� Total Garage Sq Ft �5�,
Residential Sq Ft&67 Comm'I Sq Ft N/A # of Stories ; Bldg HeightQV T.S I/# Dwelling Units 1
1 s' Floor Sq Ft rj20 2n° Floor Sq Ft 15;q" / 3^ Floor Sq Ft N/A Unfiished Bsmt Sq Ft 4"/62
Finished Bsmt Sq Ft N/A # of Bedrooms c�— # of Full Baths c;�- % Baths '/: Baths _L_# of Fireplaces
Air Conditioning: YerNo9 Energy info: ( Circle appropriate choice) 1. ComCheck 11 2. ResCheck w/Air Sealing
3. ResCheck w/Blower Door ❑ 4. Simulated Performance Alternative 6. Prescriptive w/Air Seeaaling 6. Prescriptive w/ Blower Door
City of Fort Collins Stock Plan # List appropriate option #si. 3 1 3
UTILITIES INFO:
Water Tap Size 3/4" Sewer Tap Size 4" Metered: Yes W]NoF Temp. Pedestal Yes[Z] No 11
Type of Heat: 0 Gas Electric Electric Main Breaker Size (Residential only) W1150 Amp or Less 200 Amp Other
Value of Construction (including labor, material & profit) $ F1�� 1 o
Description of
Contact Name & Phone # of JOBSITE SUPERVISOR: SHANE SENA 303-720-4616
Subcontractor Info:
Electrical ECI, INC.
Framer K & L
Solar
Mechanical FOUR SEASONS - COBB
Plumbing JOHNSON & SONS
Roofing CAMPBELL BEARD Concrete FALCON CONCRETE Fireplace AMI
Other
Other
Other
Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to comply with all requirements
contained herein and Cit Collin ordinanc and state laws regulating building construction. (Z 1
Applicant Signatur i" Print NamePhone 303-754-,14(�
Distribution: White -Office Yellow -Applicant Pink - VWWV/Stormwater
THIS APPLICATION EXPIRES 180 DAYS FROM APPLICATION DATE
updated 1-31-2012
Uty of
,Fort Collins Planning, Development & Transportation Services
' Community Development & Neighborhood Services
2012 FORT COLLINS RESIDENTIAL ENERGY CODE COMPLIANCE FORM
FORM 1 - NON -ELECTRIC HEA T (If using elec heat form 3 must be used), use this form
for single family houses, duplex, townhouses, or multi -family up to 3 stories
Permit Number:
Address:
DIRECTIONS: Place a check next to Prescriptive, UA, or SPA indicating the path chosen. An air
tightness Blower Door Test is required and must pass a 4 ACH leakage max.
(A)PRESCRIP 1i/E coml
BUILDING ENVELOPE
for house, 2009 IRC, section N1102.1, climate zone S.
INSULATION R-VALUE
(Wood frame wall insul r-value I IR-20 or 13+5ci I
Metal frame wall insul r-value
R-13+9ci or R-19+8
Crawl space wall
R-13 or R-10ci
Roof insulation in attic
R-38
Roof rafter insulation
R-30
Walls below grade
R-13 / R-loci
Wood floor over un-cond
R-30
Slab on grade floor, unheat
R-10, 24" DEEP
Windows
U-35
I I(B)TOTAL UA ALTERNATIVE (ResCheck), 2009 IRC, SECTION N1102.1.3 I
Submit a passing UA calculation (i.e. ResCheck) using 2009 IRC/IECC. The rating must be submitted at time of
application and must include address of residence; name of individual completing the rating form; name & version
of software tool (i.e. ResCheck).
(C)SIMULATED PERFORMANCE ALTERNATIVE, 2009 IECC, SECTION 405
An energy rating system must be utilized using approved computer software tool such as the new modified Fort
Collins version of RemRate. A preliminary rating passing the 2009 IECC must be submitted at time of application.
Rating must include Address, Name of individual completing the rating,& Name & version of software tool. Final
ratino reauires a blower door test, Final passing rating must be submitted for certificate of occupancy.
SIGNS
DATE:
CON CTO
R
PHONE:3os-4`d8'GU6
I