HomeMy WebLinkAbout439 NOQUET CT - DISCLOSURES - 7/29/2013 (4)FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
Date: July 29, 2013
Rating No.:
Building Name: 439 Noquet Ct
Rating Org.:
Allied Insulation
Owner's Name: Encore Homes
Phone No.:
970-223-7090
Property: 439 Noquet Ct
Raters Name:
Paul Higman
Address: Fort Collins, CO 80524
Rater's No.:
6784592
Builder's Name: Encore Homes
Weather Site: Ft Collins, CO
Rating Type:
Confirmed Rating
File Name: Encore Homes 439 Noquet Ct- Whitcomb-final.bl Rating Date:
7-29-13
Annual Energy Cost ($)
FC 2012
As Designed
Heating:
406
364
Cooling:
83
64
Water Heating:
364
364
SubTotal - Used to Determine Compliance:
853
792
Lights &Appliances:
635
637
Photovoltaics:
-0
-0
Service Charge:
204
204
Total:
1692
1632 '
Window U-Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower):
0.400
0.330
Home Infiltration (Section 402.4.2):
PASSES
Duct Leakage (Section 403.2.2):
PASSES
This home MEETS the annual energy cost requirements
and verifications of Section
405 of the 2009 International Energy
Conservation Code, amended by the City of Fort Collins.
In fact, this home surpasses the requirements by 7.2%.
Name: Paul Higman
Signature:
Organization: Allied Insulation
Date:
July 29, 2013
` Design energy cost is based on the following systems:
Heating: Fuel -fired air distribution, 64.0 kBtuh, 95.OAFUE.
Cooling: Air conditioner, 24.0 kBtuh, 13.0 SEER.
Water Heating: Conventional, Elec, 0.91 EF.
Window -to -Floor Area Ratio: 0.13
Blower door test: Htg: 1242 Clg: 1242 CFM50
Paul Digitally signed by: Paul
Higman
Higman'..."
,DN /CN = Paul Higman C = US
;Date: 2013.07.29 16:34:39 -
06'00'
L
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been
changed
prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies
are set
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
®1985-2012 Architectural Energy Corporation, Boulder, Colorado.
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
439 Noquet Ct
Page 2
equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and
software
updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum
standards.
REM/Rate -Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
01985-2012 Architectural Energy Corporation, Boulder, Colorado.
Ra y &� - -
439 Noquet Ct
Fort Collins, CO 80524
5 Stars Plus
Confirmed Rating
Uniform Energy Rating System
Energy Efficient
1 Star
j 1 Star Plus
I 2 Stars
12 Stars Plus 1 3 Stars
1 3 Stars Plus 4 Stars
4 Stars Plus
5 Stars
5 Stars Plus
500-401
1 400-301
300-251
250-201 200-151
150-101 1100-91 I
90-86
85-71
70 or Less
HERS Index: 67
j General Information
Conditioned Area: 1845 sq. ft. HouseType: Single-family detached
Conditioned Volume: 20261 cubic ft. Foundation: Conditioned crawl space
Bedrooms:
3
_._-.-__ _.,._� ._._
Mechanical Systems Features
—
Heating:
Fuel -fired air distribution, Natural gas, 95 0AFUE.
Cooling:
Air conditioner, Electric, 13.0 SEER.
Water Heating:
Conventional, Electric, 0.91 EF, 50.0 Gal.
Duct Leakage to Outside:
27.00 CFM.
Ventilation System:
Exhaust Only: 59 cfm, 24.0 watts.
Programmable Thermostat:
Heating: Yes Cooling: Yes
Building Shell Features
--
., A
. --
Ceiling Flat: R-38
Exposed Floor: NA
Vaulted Ceiling: NA
Window Type: U.0.33,SHGC0.31
Above Grade Walls: R-19
Infiltration:
Foundation Walls: R-19.0
Rate: Htg: 1242 Clg: 1242 CFM50
Slab: None
Method: Blower door test
Lights and Appliance Features
f
Percent Interior Lighting: 0.00
Range/Oven Fuel: Electric
Percent Exterior Lighting: 0.00
Clothes Dryer Fuel: Electric
Refrigerator (kWh/yr): 575.00
Clothes Dryer EF: 3.01
Dishwasher Energy Factor: 0.64
Ceiling Fan (cfm/Watt): 0.00
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
O 1985-2012 Architectural
Energy Corporation, Boulder, Colorado.
Registry ID:
Rating Number:
Certified Energy Rater:
Paul Higman
Rating Date:
7-29-13
Rating Ordered For:
Encore Homes
— Estimated
Annual Energy Cost
Confirmed Rating
Use
MMBtu
Cost
Percent
Heating
45.4
$313
20%
Cooling
1.9
$50
3%
Hot Water
13.8
$365
23%
Lights/Appliances
23.7
$625
40%
Photovoltaics
-0.0
$-0
-0%
Service Charges
$204
13%
Total
$1557
100%
_ This home meets or exceeds the minimum
criteria for all of the following:
2006 International Energy Conservation Code
2009 International Energy Conservation Code
City of Fort Collins Green Code 2012*
* Compliance with criteria for this program is
determined by the rater.
i
Digitally signed
Masco Home Services Pau I by: Paul Higman
2339 Beville Rd DN'CIV = maul
Daytona Beach, FL. 32119 Mgman C = US
3860-304-2200 �" I i g m a n Date: 2013.07.
2c'1,16:35:02 -
06'00'