Loading...
HomeMy WebLinkAbout439 NOQUET CT - DISCLOSURES - 7/29/2013 (5)r� y 1YJNSCO Contractor Services Date of Test: 7/29/2013 Customer: Encore Homes Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: BUILDING LEAKAGE TEST Test File: 439 NoquetBD Technician: Paul Higman Project Number: Building Address: 439 Noquet Fort Collins, CO 80525 1242 CFM50 (+/- 0.7 %) 3.68 ACH50 68.3 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 95.0 (+/- 5.2 %) Exponent (n) = 0.657 ( +/- 0.014 ) Correlation Coefficient = 0.99976 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 70.2CFM 0.21 ACH 2. Estimated Design Infiltration Rate: Winter: 113.1 CFM Summer: 75.1 CFM 0.33 ACH 0.22 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: ILM �i-�sco BUILDING LEAKAGE TEST Page 2 of 4 FM G:mtractor Services Date of Test: 7/29/2013 Test File: 439 NoquetBD Building Information Volume 20261 Surface Area Floor Area 1845 Height 18 # of Bedrooms 2 # of Occupants Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default ktkCon5ctracotor BUILDING LEAKAGE TEST Page 3 of 4 Rom Services Date of Test: 7/29/2013 Test File: 439 NoquetBD Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 74.0 64.0 4850.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -0.8 n/a n/a -60.5 -59.6 57.6 -54.5 -53.5 50.2 -47.7 -46.8 41.5 -42.8 -41.9 35.4 -36.7 -35.8 29.0 -31.1 -30.2 221.1 -25.0 -24.0 166.3 -18.7 -17.8 107.2 -1.0 n/a n/a Time Averaging Period: 0 None 1372 1393 -0.1 Ring A 1283 1303 0.3 Ring A 1169 1187 -0.2 Ring A 1082 1098 -0.6 Ring A 981 996 -0.1 Ring A 880 894 0.3 Ring B 765 776 1.1 Ring B 615 624 -0.8 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters at-NSco BUILDING LEAKAGE TEST Page 4 of 4 Contractor Services Date of Test: 7/29/2013 Test File: 439 Noquetl3D Comments House WRT Garage =-45.2pa