Loading...
HomeMy WebLinkAbout6802 NIMITZ DR - DISCLOSURES - 7/9/2013Y MASC,O Contractor Services `�NJlQb3bl FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: July 09, 2013 Rating No.: Building Name: Liberty 4-plex Rating Org.: Thermal Concepts Owner's Name: Lorax Construction Inc Phone No.: 970-223-7090 Property: 6802 Nimitz Dr. Blg D Rater's Name: Paul Higman Address: Ft. Collins, CO Rater's No.: 6784592 Builder's Name: Lorax Construction Weather Site: Ft. Collins, CO Rating Type: Confirmed Rating File Name: Lorax 6802 Nimitz Dr Bldg D_4plex_ final rev 7-9- Rating Date: 7-9-13 Annual Energy Cost ($) FC 2012 As Designed Heating: 1634 1510 Cooling: 374 291 Water Heating: 508 509 SubTotal - Used to Determine Compliance: 2515 2310 Lights & Appliances: 3737 3676 Photovoltaics: -0 -0 Service Charge: 816 816 Total: 7068 6801 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.363 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 8.2%. Name: Paul Higman Signature: �� _ %9-13 Organization: Thermal Concepts Date: July 09, 2013 Ir * Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 73.7 kBtuh, 92.1 AFUE. Cooling: Air conditioner, 30.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.58 EF. Window -to -Floor Area Ratio: 0.09 REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. 01985-2012 Architectural Energy Corporation, Boulder, Colorado. - FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Liberty 4-plex Blower door test: Htg: 5264 Clg: 5264 CFM50 Page 2 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. ©1985-2012 Architectural Energy Corporation, Boulder, Colorado. A(M{N Liberty 4-plex MASM 6802 Nimitz Dr. Blg D Contractor .0 Services Ft. Collins, CO Uniform Energy Rating System 5 Stars Confirmed Rating Energy Efficient 1 Star 1 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 j 100-91 90-86 85-71 70 or Less HERS Index: Conditioned Area: 11209 sq. ft. Conditioned Volume: 110678 cubic ft. Bedrooms: 11 HouseType: Multi -family, whole building Foundation: Conditioned basement Heating: Fuel -fired air distribution, Natural gas, 92.1 AFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Water Heating: Conventional, Natural gas, 0.58 EF, 50.0 Gal. Duct Leakage to Outside: 352.00 CFM. Ventilation System: Exhaust Only: 202 cfm, 24.0 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Building Shell Features Ceiling Flat: R-38 Exposed Floor: R-30, R-39 Vaulted Ceiling: NA Window Type: U:0.35, SHGC:0.31 Above Grade Walls: R-15 Infiltration: Foundation Walls: R-11.0 Rate: Htg: 5264 Clg: 5264 CFM50 Slab: R-0.0 Edge, R-0.0 Under Method: Blower door test Percent Interior Lighting: 10.00 Range/Oven Fuel: Electric Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 2300.00 Clothes Dryer EF: 3.01 Dishwasher Energy Factor: 0.64 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. ©1985-2012 Architectural Energy Corporation, Boulder, Colorado. Registry ID: Rating Number: Certified Energy Rater: Rating Date: Rating Ordered For: Paul Higman 7-9-13 Lorax Construction Inc Estimated Annual Energy Cost Confirmed Rating Use MMBtu Cost Percent Heating 181.1 $1265 19% Cooling 8.7 $228 4% Hot Water 78.8 $512 8% Lights/Appliances 139.4 $3676 57% Photovoltaics -0.0 $-0 -0% Service Charges $816 13% Total $6497 100% This home meets or exceeds the minimum criteria for all of the following: 2006 International Energy Conservation Code 2009 International Energy Conservation Code City of Fort Collins 2012 Green Code` Compliance with criteria for this program is determined by the rater. Masco Home Services 2339 Beville Rd Daytona Beach, FL. 32119 386-304-2200 -?a-0- 7�7'1,"