Loading...
HomeMy WebLinkAbout438 HOUGHTON CT - DISCLOSURES - 6/4/2013 (3)Date of Test: 6-4-13 Customer: Encore Homes Windsor, CO 80550 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College Ave Fort Collins, CO 80525 Test File: Encore Homes 438 Houghton -BD Technician: Paul Higman Project Number: Building Address: 348 Houghton Fort Collins, CO 80524 1006 CFM50 (+/- 1.1 %) 3.66 ACH50 0.6410 CFM50/ft2 floor area 63.2 in2 (+/- 5.9 %) Canadian EgLA @ 10 Pa 25.4 in2 (+/- 9.4 %) LBL ELA @ 4 Pa Flow Coefficient (C) = 23.7 ( +/- 14.7 %) Exponent (n) = 0.958 ( +/- 0.039 ) Correlation Coefficient = 0.99438 4. Test Settings: Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 25.2 CFM 0.09 ACH 2. Estimated Design Infiltration Rate: Winter: 42.9 CFM Summer: 24.1 CFM 0.16 ACH 0.09 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6-4-13 Test File: Encore Homes 438 Houghton -BD Building Information Location Climate Information Volume 16474 Surface Area Floor Area 1569 Height 16 # of Bedrooms 3 # of Occupants Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6020 Cooling Degree Days 287 Design Winter Wind Speed 9.0 mph Design Summer Wind Speed 7.0 mph Design Winter Temp Diff 69 deg F Design Summer Temp Diff 16 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 C BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6-4-13 Test File: Encore Homes 438 Houghton -BD Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) 73.0 78.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -0.8 n/a n/a -60.2 -59.4 40.4 1154 1159 -2.2 Ring A -55.1 -54.3 35.0 1076 1081 -0.6 Ring A -50.2 -49.4 29.4 989 994 0.0 Ring A -45.7 -44.9 242.6 922 926 2.2 Ring B -40.7 -39.9 201.6 841 845 4.4 Ring B -35.2 -34.4 149.4 725 728 3.8 Ring B -30.1 -29.3 91.3 568 571 -5.2 Ring B -25.5 -24.6 67.5 489 491 -3.8 Ring B -20.9 -20.0 45.0 400 402 -4.1 Ring B -0.9 n/a n/a Deviations from Standard CGSB - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6-4-13 Test File: Encore Homes 438 Houghton -BD Comments House wrt Garage =-46.4pa House wrt Mech Rm= outside conditioned space