Loading...
HomeMy WebLinkAbout451 HOUGHTON CT - DISCLOSURES - 5/17/2013 (3)Date of Test: 5-17-13 Customer: Encore Homes Windsor, CO 80550 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve 4. Test Settings: BUILDING LEAKAGE TEST Thermal Concepts P.O. Box 270066 Fort Collins, CO 80527 Test File: Encore Homes 451 Houghton BD Technician: Paul Higman Project Number: Building Address: 451 Whitcomb Fort Collins, CO 80524 995 CFM50 (+/- 0.5 %) 2.95 ACH50 0.5399 CFM50/ft2 floor area 88.5 in2 (+/- 2.9 %) Canadian EgLA @ 10 Pa 43.3 in2 (+/- 4.6 %) LBL ELA @ 4 Pa Flow Coefficient (C) = 54.6 ( +/- 7.2 %) Exponent (n) = 0.742 ( +/- 0.019) Correlation Coefficient = 0.99804 Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 42.9 CFM 0.13 ACH 2. Estimated Design Infiltration Rate: Winter: 73.1 CFM Summer: 41.1 CFM 0.22 ACH 0.12 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5-17-13 Test File: Encore Homes 451 Houghton BD Building Information Location Climate Information Volume 20261 _ Surface Area Floor Area 1843 Height 16 # of Bedrooms 2 # of Occupants Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6020 Cooling Degree Days 287 Design Winter Wind Speed 9.0 mph Design Summer Wind Speed 7.0 mph Design Winter Temp Diff 69 deg F Design Summer Temp Diff 16 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5-17-13 Test File: Encore Homes 451 Houghton BD Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) 68.0 77.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -0.8 n/a n/a -60.0 -59.1 38.5 1128 1138 0.9 Ring A -55.4 -54.5 32.8 1042 1051 -1.0 Ring A -50.7 -49.9 28.5 973 981 -1.2 Ring A -45.5 -44.6 25.3 919 927 1.3 Ring A -40.8 -39.9 193.9 825 832 -1.2 Ring B -34.9 -34.0 162.1 755 761 1.8 Ring B -29.9 -29.0 125.1 664 670 0.7 Ring B -25.2 -24.3 91.6 569 574 -1.6 Ring B -0.9 n/a n/a Deviations from Standard CGSB - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5-17-13 Test File: Encore Homes 451 Houghton BD Comments House wrt Garage =-48.5pa House wrt Mach = mechanical room is, outside