HomeMy WebLinkAbout451 HOUGHTON CT - DISCLOSURES - 5/17/2013 (2)FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: May 17, 2013 Rating No.: Building Name: 451 Houghton Rating Org.: Allied Insulation Owner's Name: Encore Homes Phone No.: 970-223-7090 Property: 451 Houghton Rater's Name: Paul Higman Address: Fort Collins, CO 80524 Rater's No.: 6784592 Builder's Name: Encore Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed Rating File Name: Encore Homes 451 Houghton -Whitcomb-final.bl Rating Date: 5-17-13 Heating: Cooling: Water Heating: SubTotal - Used to Determine Compliance: Lights &Appliances: Photovoltaics: Service Charge: Total: Annual Energy Cost ($) 17NRY 13 3:57PPI FC 2012 As Designed 406 350 83 64 134 84 - - - 622 --- — - - - 499 --- - -- --- -- 635 637 -0 -0 204 204 1461 1339 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.330 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES jThis home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 19.8%. Name: Paul Higman Signature: Organization: Allied Insulation Date: May 17, 2013 - Digitally -signed by: -Paul ' Design energy cost is based on the following systems: Paul Higman Heating: Fuel -fired air distribution, 64.0 kBtuh, 95.OAFUE. Cooling:Air conditioner, 24.0 kBtuh, 13.0 SEER. DIN: CN = Paul Higman C = US Water Heating: Instant water heater, Gas, 0.98EF. Higman fbate:2013.05.1711:20:03- Wind ow -to -Floor Area Ratio:0.13 " 06;001 Blower door test: Htg: 995 Clg: 995 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. 01985-2012 Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT 451 Houghton Page 2 equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate -Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. © 1985-2012Architectural Energy Corporation, Boulder, Colorado. v 451 Houghton Fort Collins, CO 80524 5 Stars Plus Confirmed Rating Uniform Energy Rating System Energy Efficient 1 Star I 1 Star Plus I 2 Stars [2StarsPIus_, 3 Stars 13 Stars Plus 4 Stars 14 Stars Plus 15 Stars 15 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less HERS Index: 56 General Information Conditioned Area: 1845 sq. ft. HouseType: Single-family detached Conditioned Volume: 20261 cubic ft. Foundation: Conditioned crawl space Bedrooms: 3 Mechanical Systems Features Heating: Fuel -fired air distribution, Natural gas, 95.OAFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Water Heating: Instant water heater, Natural gas, 0.98 EF, 0.0 Gal. Duct Leakage to Outside: 27.00 CFM. Ventilation System: Exhaust Only: 59 cfm, 24.0 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Building Shell Features Ceiling Flat: R-38 Exposed Floor: NA Vaulted Ceiling: NA Window Type: U.0.33,SHGCO.31 Above Grade Walls: R-19 Infiltration: Foundation Walls: R-19.0 Rate: Htg: 995 Clg: 995 CFM50 Slab: None Method: Blower door test Lights and Appliance Features Percent Interior Lighting: 0.00 Range/Oven Fuel: Electric Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric Refrigerator (kWhtyr): 575.00 Clothes Dryer EF: 3.01 Dishwasher Energy Factor: 0.64 Ceiling Fan (cfm/ Waft): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. O 1985-2012 Architectural Energy Corporation, Boulder, Colorado. Registry ID: Rating Number: Certified Energy Rater: Paul Higman Rating Date: 5-17-13 Rating Ordered For: Encore Homes Estimated Annual Energy Cost Confirmed Rating Use MMBtu Cost Percent Heating 43.6 $301 24% Cooling 1.9 $51 4% Hot Water 13.0 $84 7% Lights/Appliances 23.7 $625 49% Photovoltaics -0.0 $-0 -0% Service Charges $204 16% Total $1265 100% This home meets or exceeds the minimum criteria for all of the following: 2006 International Energy Conservation Code 2009 International Energy Conservation Code City of Fort Collins Green Code 2012' Compliance with criteria for this program is determined by the rater. Digitally signed Masco Home Services Pau I by: Paul Higman 2339 Beville Rd DN` CN = Paul Daytona Beach, FL.32119 Higman C = US 3860-304-220o H i g m a n'Date: 2013.05. 17 11:20:24 - 06'00'