HomeMy WebLinkAbout945 RIDGE RUNNER DR - DISCLOSURES - 5/13/2013BURGESS AIR LEAKAGE REPORT Date: May 13, 2013 Rating No.: Worst Case Scenario DE Building Name: DR Horton1400 Rating Org.: Burgess, Inc Owner's Name: DR Horton Phone No.: 303-300-4527 Property: 945 Ridge Runner Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO 80524 Rater's No.: 7479033 Builders Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 945 Ridge Runner Drive.blg Rating Date: 5/10/2013 Whole House Infiltration Duct Leakage Ventilation Blower door test Heating I Cooling Natural ACH: 0.201 0.15 ACH @ 50 Pascals: 3.19 3.19 CFM @ 25 Pascals: 581 581 CFM @ 50 Pascals: 911 911 Eff. Leakage Area: (sq.in] 50.0 50.0 Specific Leakage Area: 0.00017 0.00017 ELA/100 sf shell: [sq.in] 1 1.001 1.00 Leakage to Outside Units ducts CFM @ 25 Pascals: 19 CFM25 / CFMfan: 0.0146 CFM25 /CFA: 0.0091 CFM per Std 152: N/A CFM per Std 152 / CFA: N/A CFM @ 50 Pascals: 30 Eff. Leakage Area: [sq.in] 1.64 Thermal Efficiency: N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage: 0.0447 Mechanical: Exhaust Only Sensible Recovery Eff. (%): 0.0 Total Recovery Eff. (%): 0.0 Rate (cfm): 43 Hours/Day: 24.0 Fan Watts: 11.3 Cooling Ventilation: Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings, a minimum of 43 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 87 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate - Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. 01985-2013 Architectural Energy Corporation, Boulder, Colorado. BURGESS lei {.'ka��lrr�Q.`' V H'IiiW COMPONENT LOAD SUMMARY Date: May 13, 2013 Rating No.: Worst Case Scenario DE Building Name: DR Horton1400 Rating Org.: Burgess, Inc Owner's Name: DR Horton Phone No.: 303-300-4527 Property: 945 Ridge Runner Drive Raters Name: Robert Hutchinson Address: Fort Collins, CO 80524 Rater's No.: 7479033 Builder's Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 945 Ridge Runner Drive.blg Rating Date: 5/10/2013 DR Horton1400 HEATING SEASON (MMBtu/yr) Ceilings/Roofs 5.0 Rim/Band Joists 2.6 Above Grade Walls 18.5 Foundation Walls 9.5 Doors 1.8 Windows/Skylights 7.0 Frame Floors 1.7 Crawl Space/Unht Bsmt 0.0 Slab Floors 2.5 Infiltration 4.5 Mechanical Ventilation 7.0 Ducts 2.0 Active Solar 0.0 Sunspace 0.0 Internal Gains -15.1 Total 47.1 DR Horton1400 REM/Rate - Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. © 1985-2013 Architectural Energy Corporation, Boulder, Colorado. Ij cev{ COPY BUILDING LEAKAGE TEST Date of Test: 5/10/2013 Test File: DR Horton Blower door Customer: DR Horton 7600 E Orchard Rd #350-S Greenwood Village, Colorado 80111 Phone Test Results Technician: Doug Groff Building Address: 945 Ridge Runner Drive Fort Collins, Colorado 80524 1. Airflow at 50 Pascals: 894 CFM (+/- 0.4 %) (50 Pa = 0.2 w.c.) 3.13 ACH 0.43 CFM per ft2 floor area 2. Leakage Areas: 215.7 in2 (+/ 4.3 %) Canadian EgLA @ 10 Pa 186.0 in2 (+/ 6.6 %) LBL ELA @ 4 Pa 3. Minneapolis Leakage Ratio: 0.18 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 553.9 ( +/- 10.2 %) Exponent (n) = 0.122 ( +/- 0.026 ) Correlation Coefficient = 0.94048 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 190.1 CFM 0.67 ACH 2. Estimated Design Infiltration Rate: Winter: 314.4 CFM 1.10 ACH Summer: 178.6 CFM 0.63 ACH 3. Recommended Whole Building Mechanical 0.0 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: .l BUILDING LEAKAGE TEST Page 2 Date of Test: 5/10/2013 Test File: DR Horton Blower door Building Conditions Inside Temperature: 73 deg F Outside Temperature: 48 deg F # of Stories 2.0 Wind Shield: M # of Occupants # of Bedrooms: 2.0 Volume: 17144 ft3 Surface Area: 5019 ft2 Floor Area: 2080 ft2 Design Winter Wind Speed: 9.0 mph Design Summer Wind Speed: 7.0 mph Heating Fuel: Gas Heating Fuel Cost: Heating Efficiency: Heating Degree Days: 6020 Cooling Fuel Cost: Cooling SEER: Cooling Degree Days: 287 Ventilation Weather Factor: 0.87 Energy Climate Factor: 17.0 Design Winter Temp Diff: 69 deg F Design Summer Temp Diff: 16 deg F Comments Garage WRT House: 45PA @ 50 PA :? BUILDING LEAKAGE TEST Page 3 Date of Test: 5/10/2013 Test File: DR Horton Blower door Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -1.9 n/a +/- 0.00 -65.0 257.2 949 926 0.8 Ring B -60.0 248.5 933 911 0.1 Ring B -60.0 242.6 922 900 -1.1 Ring B -50.0 236.8 911 889 -0.0 Ring B -45.0 231.6 901 880 0.2 Ring B Air Leakage Property Organization DR Horton Burgess, Inc 945 Ridge Runner Drive 303-300-4527 Fort Collins, CO 80524 Robert Hutchinson Weather:Ft. Collins, CO Builder DR Horton1400 DR Horton 945 Ridge Runner Drive.blg Whole House Infiltration Natural ACH ACH @ 50 Pascals CFM @ 50 Pascals Eff. Leakage Area (sq.in) Specific Leakage Area ELA/100 sf shell (sq.in) Duct Leakage Leakage to Outside Units ducts CFM @ 25 Pascals 0 CFM25 / CFMfan 0.0000 CFM25 / CFA 0.0000 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 0 Eff. Leakage Area (sq.in) 0.00 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0447 Ventilation Mechanical Sensible Recovery Eff. (%) Total Recovery Eff. (%) Rate (cfm) Hours/Day Fan Watts Cooling Ventilation HERS Projected Rating 9/28/2012 Rating No:Worst Case Scenario RaterID:7479033 Blower Door Test Heating I Cooling BURGESS Es CONSTRUCTION CONSULTANTS INC. 0.20 3.19 0.15 3.19 581 581 911 911 50.0 50.0 0.00017 0.00017 1.00 1.00 Exhaust Only 0.0 0.0 43 24.0 11.3 Natural Ventilation SINCE 1986 ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable Indoor Air Quality in Low Rise Residential Buildings, a minimum of 43 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 87 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate - Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. 01985-2013 Architectural Energy Corporation, Boulder, Colorado.