HomeMy WebLinkAbout427 STONEY BROOK RD - DISCLOSURES - 4/7/2013Date of Test: 4-7-13 Customer: Journey Homes Greeley, CO 80634 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: 4. Test Settings: BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College Ave Fort Collins, CO 80525 Test File: Journey Homes 427 StoneyBrook-BD Technician: Paul Higman Project Number: Building Address: 427 Stoney Brook Fort Collins, CO 80525 981 CFM50 (+/- 0.6 %) 2.62 ACH50 0.4067 CFM50/ft2 floor area 122.5 in2 ( +/- 2.2 %) Canadian EgLA @ 10 Pa 72.7 in2 (+/- 3.6 %) LBL ELA @ 4 Pa Flow Coefficient (C) = 122.5 ( +/- 5.8 %) Exponent (n) = 0.532 ( +/- 0.016 ) Correlation Coefficient = 0.99733 Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 72.0 CFM 0.19ACH Winter: 122.7 CFM Summer: 68.9 CFM 0.33 ACH 0.18 ACH BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 4-7-13 Test File: Journey Homes 427 StoneyBrook-BD Building Information Location Climate Information Volume 22477 Surface Area Floor Area 2413 Height 16 # of Bedrooms 3 # of Occupants Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6020 Cooling Degree Days 287 Design Winter Wind Speed 9.0 mph Design Summer Wind Speed 7.0 mph Design Winter Temp Diff 69 deg F Design Summer Temp Diff 16 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 4-7-13 Test File: Journey Homes 427 StoneyBrook-BD Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) 65.0 42.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.2 n/a n/a -55.5 -54.2 32.6 1040 1017 -0.7 Ring A -50.2 48.9 29.2 985 963 -0.7 Ring A -45.3 -44.0 264.4 962 941 2.6 Ring B -40.5 -39.2 221.4 881 861 -0.1 Ring B -35.1 -33.8 184.5 805 787 -1.2 Ring B -30.4 -29.1 160.4 751 734 -0.2 Ring B -25.1 -23.8 130.5 678 663 0.3 Ring B -20.3 -19.0 101.6 599 586 -0.1 Ring B -1.4 n/a n/a Deviations from Standard CGSB - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 4-7-13 Test File: Journey Homes 427 StoneyBrook-BD Comments House WRT Garage -48.1 pa House WRT Mechanical Rm = Elect water heat