Loading...
HomeMy WebLinkAbout427 HOUGHTON CT - DISCLOSURES - 4/18/2013 (2)Date of Test: 4-18-13 Customer: Encore Homes Windsor, CO 80550 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: 4. Test Settings: BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College Ave Fort Collins, CO 80528 Test File: Encore Homes 427 Houghton -BD Technician: Paul Higman Project Number: Building Address: 427 Houghton Fort Collins, CO 80524 1175 CFM50 (+/- 1.4 %) 3.87 ACH50 0.7410 CFM50/ft2 floor area 122.1 in2 ( +/- 9.5 %) Canadian EgLA @ 10 Pa 65.3 in2 (+/- 15.1 %) LBL ELA @ 4 Pa Flow Coefficient (C) = 94.0 ( +/- 23.5 %) Exponent (n) = 0.646 ( +/- 0.061 ) Correlation Coefficient = 0.98263 Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 64.7 CFM 0.21 ACH 2. Estimated Design Infiltration Rate: Winter: 110.2 CFM Summer: 61.8 CFM 0.36 ACH 0.20 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 4-18-13 Test File: Encore Homes 427 Houghton -BD Building Information Location Climate Information Volume 18207 Surface Area Floor Area 1585 Height 16 # of Bedrooms 3 # of Occupants Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6020 Cooling Degree Days 287 Design Winter Wind Speed 9.0 mph Design Summer Wind Speed 7.0 mph Design Winter Temp Diff 69 deg F Design Summer Temp Diff 16 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 4-18-13 Test File: Encore Homes 427 Houghton -BD Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (OF) 67.0 38.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.8 n/a n/a -61.7 -59.8 55.6 1349 1311 -0.5 Ring A -55.4 -53.4 46.0 1230 1196 -2.5 Ring A -50.3 -48.3 45.3 1221 1187 3.3 Ring A -45.5 -43.5 38.8 1132 1100 2.4 Ring A -36.3 -34.3 230.6 899 874 -5.2 Ring B -31.2 -29.3 214.8 868 844 1.5 Ring B -2.1 n/a n/a Deviations from Standard CGSB - Test Parameters - Correlation coefficient (0.983) outside of acceptable limits. - Test data was not collected at all 8 recommended target building pressures. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 4-18-13 Test File: Encore Homes 427 Houghton-13D Comments House WRT Garage =-45.6pa house WRT mech room = Outside building Envelope