Loading...
HomeMy WebLinkAbout427 HOUGHTON CT - DISCLOSURES - 4/18/2013Registry ID: Rating Number: Certified Energy Rater: Paul Higman 427 Houghton Rating Date: 4-18-13 Rating Ordered For: Encore Homes Fort Collins, CO 80524 A 5 Stars Confirmed Rating Uniform Energy Rating System Energy Efficient 1 Star 1 Star71us Slars 2 Stars Plus 3 Stars 3 Stars Plus4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401_{-_400_-300.251 _ 250_207 200-151 f 150-1011100-91 f — 90-86- 85-71 70 or Less HERS Index: 71 General Information Conditioned Area: Conditioned Volume: Bedrooms: Mechanical Systems Features Heating: Cooling: Water Heating: Duct Leakage to Outside: Ventilation System: Programmable Thermostat: Building Shell Features Ceiling Flat: Vaulted Ceiling: Above Grade Walls: Foundation Walls: :yF11:1111 1585 sq. ft. HouseType: Single-family detached 18207 cubic ft. Foundation: Conditioned crawl space 3 Fuel -fired air distribution, Natural gas, 95.OAFUE. Air conditioner, Electric, 13.0 SEER. Conventional, Electric, 0.95 EF, 50.0 Gal. 36.00 CFM. Exhaust Only: 69 cfm, 24.0 watts. Heating: Yes Cooling: Yes R-38 Exposed Floor: NA NA Window Type: U.0.33,SHGCO.31 R-19 Infiltration: R-19.0 None Rate: Htg: 1175 Clg: 1175 CFM50 Method: Blower door test Estimated Annual Energy Cost Confirmed Rating Use MMBtu Cost Percent Heating 42.5 $293 20% Cooling 2.1 $55 4% Hot Water 13.3 $352 24% Lights/Appliances 22.2 $584 39% Photovoltaics -0.0 $-0 -0% Service Charges $204 14% Total $1488 100% This home meets or exceeds the minimum criteria for all of the following: 2009 International Energy Conservation Code City of Fort Collins Green Code 2012' Compliance with criteria for this program is determined by the rater. Lights and Appliance Features Digitally signed Percent Interior Lighting: 0.00 Range/Oven Fuel: Electric Masco Home Services by: Paul Higman Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric 2339 Beville Rd P a u I DN': CN = Paul Refrigerator (kWh/yr): 575.00 Clothes Dryer EF: 3.01 Daytona Beach, FL. 32119 Higman C = US Dishwasher Energy Factor: 0.64 Ceiling Fan (cfmNVatt): 0.00 3860-304-2200 Higman IT Dat „e: 2013.04. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. - 1 8'16:20:12 - REM/Rate - Residential Energy Analysis and Rating Software v12.97 06 00 This information does not constitute any warranty of energy cost or savings. 0 1985-2012 Architectural Energy Corporation, Boulder, Colorado. , FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: April 18, 2013 Building Name: 427 Houghton Owner's Name: Encore Homes Property: 427 Houghton Address: Fort Collins, CO80524 Builder's Name: Encore Homes Weather Site: Ft. Collins, CO File Name: Encore Homes 427 Houghton-Garfield-final.blg Rating No.: Rating Org.: Thermal Concepts Phone No.: 970-223-7090 Rater's Name: Paul Higman Rater's No.: 6784592 Rating Type: Confirmed Rating Rating Date: 4-18-13 Annual Energy Cost ($) --- -- -- - -- - --- Heating: Cooling: Water Heating: SubTotal - Used to Determine Compliance: Lights &Appliances: Photovoltaics: Service Charge: Total: - -- — — ------ - --- - - — ---- Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): FC 2012 As Designed 361 341 79 68 352 352 592 594 -0 -0 204 204 1587 1559 0.400 0.330 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 3.9%. Name: Paul Higman _ _ _ Signature:" Organization: Thermal Concepts Date: April 18, 2013 - - ---- - - - - - - — 1��1+ -- -- --Digitally signed-by:-Paul Design energy cost is based on the following systems: 1 I Hlgm' an Heating: Fuel -fired air distribution, 64.0 kBtuh, 95.0AFUE. DN:.CN = Paul Higman C = Cooling: Air conditioner, 24.0 kBtuh, 13.0 SEER. I ry YYl �Y't y I 1 1 11 rUS Water Heating: Conventional, :Elec,0.1 0.95 EF. Date: 2013.04.18 16:19:52 - Window-to-FloorArea Ratio: 0.14 � 06�00� Blower door test: Htg: 1175 Clg: 1175 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. © 1985-2012Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT 427 Houghton Page 2 equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate -Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. ©1985-2012Architectural Energy Corporation, Boulder, Colorado.