Loading...
HomeMy WebLinkAbout432 BOW CREEK LN - DISCLOSURES - 3/9/2013 (2)BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College Ave Fort Collins, CO 80525 Phone: 970-223-7090 Date of Test: 3-9-13 Test File: Journey Homes 432 Bow Creek -BD Customer: Journey Homes Greeley, CO 80634 Phone _-. . Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: Infiltration Estimates Technician: Paul Higman Building Address: 432 Bow Creeek Fort Collins, CO 80525 972 CFM (+/- 0.6 %) 2.59 ACH 0.40 CFM per ft2 floor area 118.7 in2 ( +/- 2.1 %) Canadian EgLA @ 10 Pa 69.4in2(+/-3.5%)LBLELA@4Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 114.9 ( +/- 5.6 %) Exponent (n) = 0.546 ( +/- 0.015 ) Correlation Coefficient = 0.99765 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 1. Estimated Average Annual Infiltration Rate: 80.2 CFM 0.21 ACH 2. Estimated Design Infiltration Rate: Winter: 117.3 CFM 0.31 ACH Summer: 66.7 CFM 0.18 ACH 3. Recommended Whole Building Mechanical 38.2 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 3-9-13 Test File: Journey Homes 432 Bow Creek -BD Building Conditions Inside Temperature: 68 deg F Outside Temperature: 28 deg F # of Stories 2.0 Wind Shield: M # of Occupants # of Bedrooms: 3.0 Volume: 22477 ft3 Surface Area: Floor Area: ...... _ _ 2413 ft2 Design Winter Wind Speed: 9.0 mph Design Summer Wind Speed: 7.0 mph Heating Fuel: Gas Heating Fuel Cost: Heating Efficiency: Heating Degree Days: 6020 Cooling Fuel Cost: Cooling SEER: Cooling Degree Days: 287 Ventilation Weather Factor: 0.87 Energy Climate Factor: 17.0 Design Winter Temp Diff: 69 deg F Design Summer Temp Diff: 16 deg F Comments House WRT Garage -47.3 pa House WRT Mechanical Rm = Elect water heater BUILDING LEAKAGE TEST Page 3 Date of Test: 3-9-13 Test File: Journey Homes 432 Bow Creek -BD Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -1.2 n/a +/- 0.00 -55.5 34.1 1062 1021 0.5 Ring A -50.2 29.2 985 947 -1.4 Ring A -45.3 264.4 962 925 2.0 Ring B -40.5 221.4 881 847 -0.5 Ring B -35.1 184.5 805 774 -1.4 Ring B 730.4 160.4 751 722 -0.2 Ring B -25.2 130.5 678 652 0.3 Ring B -20.2 101.6 599 576 0.7 Ring B -1.4 n/a +/- 0.00