Loading...
HomeMy WebLinkAbout426 TORONTO ST - DISCLOSURES - 3/9/2013 (2)BUILDING LEAKAGE TEST Thermal Concepts P.O. Box 270066 Fort Collins, CO 80527 Phone: 970-223-7090 Date of Test: 3-9-13 Technician: Paul Higman Test File: Encore Homes 426 Toronto -BD Customer: Encore Homes Building Address: 426 Toronto Fort Collins, CO 80524 Windsor, CO 80550 Phone Test Results 1. Airflow at 50 Pascals: 867 CFM (+/- 0.7 %) (50 Pa = 0.2 w.c.) 3.51 ACH 0.56 CFM per ft2 floor area 2. Leakage Areas: 79.5 in2 (+/- 3.0 %) Canadian EgLA @ 10 Pa 39.5in2(+/-4.8%)LBLELA@4Pa 3. Minneapolis Leakage Ratio: 0.00 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 51.1 ( +/- 7.7 %) Exponent (n) = 0.724 ( +/- 0.021 ) Correlation Coefficient = 0.99754 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 47.1 CFM 0.19 ACH 2. Estimated Design Infiltration Rate: Winter: 66.8 CFM 0.27 ACH Summer: 38.0 CFM 0.15 ACH 3. Recommended Whole Building Mechanical 29.8 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 3-9-13 Test File: Encore Homes 426 Toronto -BD Building Conditions Inside Temperature: 62 deg F Heating Fuel: Gas Outside Temperature: 28 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 2.0 Volume: 14820 ft3 Ventilation Weather Factor: 0.87 Surface Area: Energy Climate Factor: 17.0 Floor Area: 1542 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments House wrt Garage = -46.1 pa House wrt Mech = mechanical room is outside BUILDING LEAKAGE TEST Page 3 Date of Test: 3-9-13 Test File: Encore Homes 426 Toronto -BD Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -1.2 n/a +/- 0.00 -55.1 255.0 945 914 -0.3 Ring B -50.3 217.8 874 845 -1.4 Ring B -45.2 192.9 823 796 0.5 Ring B -41.6 175.4 785 759 1.9 Ring B -35.6 132.0 682 659 -0.5 Ring B -30.5 111.4 627 606 2.7 Ring B -25.5 77.9 525 508 -1.6 Ring B -20.4 54.5 440 425 -2.3 Ring B -1.0 n/a +/- 0.00