HomeMy WebLinkAbout839 CAMPFIRE DR - DISCLOSURES - 1/28/2013 (2)BURGESS We] CONSTRUCTION CONSULTANTS INC. S.CE I. AIR LEAKAGE REPORT Date: January 28, 2013 Rating No.: Worst Case Scenario DE Building Name: 2015 Rating Org.: Burgess Inc. Owners Name: DR Horton Phone No.: 303-3004527 Property: 839 Campfire Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO80524 Raises No.: 7470933 Builders Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 839 Campfire Drive.blg Rating Date: 1/28/2013 Whole House Infiltration Duct Leakage Ventilation Blower door test Heating Cooling NaturalACH: 0.17 0.13 ACH @ 50 Pascals: 2.69 2.69 CFM @ 25 Pascals: 726 726 CFM @ 50 Pascals: 1140 1140 Eff. Leakage Area: [sq.in] 62.6 62.6 Specific Leakage Area: 0.00014 0.00014 ELAM 00 sf shell: [sq.in] 0.85 0.85 Leakage to Outside Units Hvac CFM @ 25 Pascals: 0 CFM25 / CFMfan: 0.0000 CFM25 / CFA: 0.0000 CFM per Std 152: N/A CFM per Std 152 / CFA: N/A CFM @ 50 Pascals: 0 Eff. Leakage Area: [sq.in] 0.00 Thermal Efficiency: N/A Total Duct Leakage Units CFM251CFA Total Duct Leakage: 0.0477 Mechanical: Exhaust Only Sensible Recovery Eff. (%): 0.0 Total Recovery Eff. (%): 0.0 Rate (cfm): 60 Hours/Day: 24.0 j Fan Watts: 11.3 Cooling Ventilation: Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable IndoorAir Quality in Low -Rise Residential Buildings, a minimum of60 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 121 cfin mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. 0 1985-2012 Architectural Energy Corporation, Boulder, Colorado. BUILDING LEAKAGE TEST Date of Test: 1/28/2013 Technician: Doug Groff Test File: DR Horton Blower door Customer: DR Horton Building Address: 839 Campfire Drive 7600 E Orchard Rd #350-S Fort Collins, Colorado 80524 Greenwood Village, Colorado 80111 Phone Test Results 1. Airflow at 50 Pascals: 1107 CFM (+/ 0.1 %) (50 Pa = 0.2 w.c.) 2.61 ACH 0.36 CFM per ft2 floor area 2. Leakage Areas: 261.0 in2 (+/ 0.6 %) Canadian EgLA @ 10 Pa 222.1 in2 (+/ 1.0 %) LBL ELA @ 4 Pa 3. Minneapolis Leakage Ratio: 0.15 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 647.9 ( +/- 1.5 %) Exponent (n) = 0.137 ( +/- 0.004 ) Correlation Coefficient = 0.99883 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 230.1 CFM 0.54 ACH 2. Estimated Design Infiltration Rate: Winter: 375.3 CFM 0.89 ACH Summer: 213.3 CFM 0.50 ACH 3. Recommended Whole Building Mechanical 0.0 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 1/28/2013 Test File: DR Horton Blower door Building Conditions Inside Temperature: 67 deg F Heating Fuel: Gas Outside Temperature: 32 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 3.0 Volume: 25437 ft3 Ventilation Weather Factor: 0.87 Surface Area: 7323 11:2 Energy Climate Factor: 17.0 Floor Area: 3043 112 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments Garage WRT House: 45.0 Pa @ 50 Pa M BUILDING LEAKAGE TEST Page 3 Date of Test: 1 /28/2013 Test File: DR Horton Blower door Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -1.7 n/a +/ 0.00 -65.0 42.6 1185 1145 0.1 Ring A -60.0 41.5 1170 1130 -0.0 Ring A -55.0 40.5 1155 1116 . -0.1 Ring A -50.0 39.4 1140 1101 -0.1 Ring A -45.0 38.3 1125 1087 0.1 Ring A