Loading...
HomeMy WebLinkAbout839 CAMPFIRE DR - DISCLOSURES - 1/28/2013r Registry to: 482470752 BUAUJJ .i/i Rating Number: Worst Case Scenario DE �J VV��''��'' Certified Energy Rater: Robert Hutchinson ^�7LL � f 2015 I 1V� [}�� Rating Dale: 1/28/2013 839 Campfire Drive l� Rating Ordered For: DR Horton Fort Collins, CO 80524 CONSTRLCfION Ir.��, �� Estimated Annual Energy Cost � _ (ONSCLTANTS ' ` ter' �'r� Confirmed _ INC_ _ � ' 5 Stars Plus Use MMBtu Cost Percent Confirmed Heating 68.3 $473 29% Cooling 0 $0 0% Uniform Energy Rating System Energy Efficient Hot Water 19.2 $125 8 % 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus Lights/Appliances 31.6 $834 51% 500-401 400-301 300 251 250-201 200 151 150 101. 100-91 90-86 85-71 70 or Less Photovoltaics -0.0 $-0 -0% HERS Index: 67 Service Charges $204 12% General Information Total $1636 100 % Conditioned Area: 3043 sq. ft. HouseType: Single-family detached Conditioned Volume: 25437 cubic ft. Foundation: Conditioned basement This home meets or exceeds the minimum Bedrooms: 3 MechanicallSystemsFeatufe5 - criteria for all of the following: - EPA ENERGY STAR Version 2 Home Heating: Fuel -fired air distribution, Natural gas, 92.OAFUE. 2006 International Energy Conservation Code Water Heating: Conventional, Natural gas, 0.62 EF, 40.0 Gal. 2009 International Energy Conservation Code Duct Leakage to Outside: 0.00 CFM. Ventilation System: Exhaust Only: 60 cfm, 11.3 watts. Programmable Thermostat: Heating: Yes Coaling: Yes 'Building Shell Features Ceiling Flat: R-38 Exposed Floor: R-30 Vaulted Ceiling: NA Window Type: Double -Vinyl 3530""""""' Above Grade Walls: R-15, R-19 Infiltration: Foundation Walls: R-11.0 Rate: Htg: 1140 Clg: 1140 CFM50 Slab: R-0.0 Edge, R-0.0 Under Method: Blower door test - Lights and Appliance Features MOO AGF/ Percent Interior Lighting. 10.00 Range/Oven Fuel Electric Burgess Construction Consultant 'o/ \COL Percent Garage Lighting: 0,00 Clothes Dryer Fuel: Electric 1255 W. 15th St Suite 1000 Refrigerator kWh r: 775.00 ClothesD Dryer EF: 2.67 9 ( N) 7 Plano, Texas 75075 Dishwasher Energy Factor: 0.68 Ceiling Fan (cfmfWatt): 0.00 214-291-3141 z No `rt�sa�aa e e The Home Energy Rating Standard Disclosure for this home is available from the rating provider. 214-291-3142 'gypsy L / egg � REM/Rate - Residential Energy Analysis and Rating Software v13.0 n / (e� 7479033 c„eo This information does not constitute any warranty of energy cost or savings. !,(t�L�A © 1985-2012 Arc hi tectural Energy Corporation, Boulder, Colorado. - Certified Energy Rater JI+ I BURGESS We CONSTRUCrION CONSULTANIS INC. SINCE. 1. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: January 28, 2013 Rating No.: Worst Case Scenario DE Building Name: 2015 Rating Org.: Burgess Inc. Owner's Name: DR Horton Phone No.: 303-3004527 Property: 839 Campfire Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO 80524 Rater's No.: 7470933 Builder's Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 839 Campfire Drive.blg Rating Date: 1/28/2013 Annual Energy Cost ($) FC 2012 As Designed Heating: 528 553 Cooling: 131 91 Water Heating: 124 124 SubTotal - Used to Determine Compliance: 783 768 Lights &Appliances: 847' 834 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1834 1806 " Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.340 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 2.0%. Name: Robert Hutchinson Organization: Burgess Inc. Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 80.0 kBtuh, 92.0AFUE. Water Heating: Conventional, Gas, 0.62 EF. Cooling: Air conditioner, 18.5 kBtuh, 13.0 SEER. Window -to -Floor Area Ratio:0.13 Signature: Date: January28, 2013 REM/Rate -Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. C 1985-2012Archdectural Energy Corporation, Boulder, Colorado. 2015 FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Page 2 Blower door test Htg: 1140 Clg: 1140 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software A 3.0 This information does not constitute any warranty of energy cost or savings. 01985-2012 Architectural Energy Corporation, Boulder, Colorado.