Loading...
HomeMy WebLinkAbout421 BANNOCK ST - DISCLOSURES - 1/19/2013I L F%jte ol YYGCertified ec Registry ID: Rating Number: Energy Rater: Paul Higman Rating Date: 1-19-13 421 Bannock ii Rating Ordered For: Encore Homes Fort Collins, CO 80524 t7 A A A- 5 Stars Plus Confirmed Rating Uniform Energy Rating System Energy Efficient F1 tar 1 Star Plus 2 Stars -3 Stars Plus —2—Stars Plus 3 Star F4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 59s, 250-201 0-151 L HERS Index: 64 General Information, Conditioned Area: 2288 sq. ft. HouseType: Single-family detached Conditioned Volume: 16392 cubic ft. Foundation: Conditioned crawl space Bedrooms: 3 Mechanical -s ystemsFeatures Heating: Fuel -fired air distribution, Natural gas, 95.OAFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Water Heating: Conventional, Electric, 0.95 EF 50.0 Gal. Duct Leakage to Outside: 38.00 CFM. Ventilation System: Exhaust Only:65 cfm, 24.0 watts. Programmable Thermostat Heating: Yes Cooling: Yes Building Shell Features Ceiling Flat: R-38 Exposed Floor R-38 Vaulted Ceiling: NA Window Type: U.0.33.SHGCO.31 Above Grade Walls: R-1 9, R-1 5 Infiltration: Foundation Walls: R-1 9.0 Rate: Htg: 1002 Clg: 1002 CFM50 Slab: None Method: Blower door test Lights and Appliance Features Percent Interior Lighting: 0.00 Range/Oven Fuel: Electric Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric Refrigerator (kWhtyr): 575.00 Clothes Dryer EF: 3.01 Dishwasher Energy Factor: 0.64 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v1 2.97 This information does not constitute any warranty of energy cost or savings. 0 1985-2012 Architectural Energy Corporation, Boulder, Colorado. Estimated Annual Energy Cost Confirmed Rating Use MmBtu Cost Percent Heating 37.6 $203 15% Cooling 2.5 $58 4% Hot Water 13.3 $313 23% Lights/Appliances 26.4 $618 45% Photovoltaics -0.0 $_0 _0% Service Charges $180 13% Total $1372 7 7' 100% This home meets or exceeds the minimum criteria for all of the following: Digitally signed Masco Home Services by: Paul Higman 2339 Beville Rd P a u I' DN':CN = Paul Daytona Beach FIL 32119 n" "'I" an C = US 3860-304-2200' Higma ) Hbat'0: 2013.01. 22�'M0:48:38 - 06'00' FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: January 22, 2013 Rating No.: Building Name: 421 Bannock Rating Org.: Owners Name: Encore Homes Phone No.: Property: 421 Bannock Rater's Name: Address: Fort Collins, CO 80524 Rater's No.: Builders Name: Encore Homes LLC Weather Site: Ft. Collins, CO Rating Type: File Name: Encore Homes 421 Bannock- Remington-final.bl, Rating Date: Heating: Cooling: Water Heating: SubTotal - Used to Determine Compliance: Lights &Appliances: Photovoltaics: Service Charge: Total Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): Home Infiltration (Section 402.4.2): Duct Leakage (Section 403.2.2): Thermal Concepts 970-223-7090 Paul Higman 6784592 Confirmed Rating 1-19-13 Annual Energy Cost ($) FC 2012 As Designed 269 237 78 71 1313 313 659 621 630 630 -0 -0 180 180 1469 1431 ' 0.400 0.334 PASSES PASSES This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 5.9W j Name: Paul Higman Signature: Organization: Thermal Concepts Date: January 22, 2013 Paul Digitally -signed -by -Paul Design energy cost is based on the following systems: Higman Heating: Fuel -fired air distribution, 64.0 kBtuh, 95.OAFUE. n DN CN = Paul Higman C = US Cooling: Air conditioner, 30.0 kBtuh, 13.0 SEER. Higman 1 W� lal 1 J,bate: 2013.01.22 10:48:11 - Water Heating: Conventional, Elec, 0.95 EF. J1061001 Window -to -Floor Area Ratio: 0.10 Blower door test: Htg: 1002 Clg: 1002 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed ' prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set REM/Rate -Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. ©1985-2012Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT 421 Bannock Page 2 equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software 02.97 This information does not constitute any warranty of energy cost or savings. ©1985-2012 Architectural Energy Corporation, Boulder, Colorado.