HomeMy WebLinkAbout421 SAN JUAN DR - SPECIAL INSPECTIONS - 8/28/2012T
S
4E
TOTAL ENGINEERING SERVICE, INC.
1601 37" ST. • EVANS, COLORADO 80620 • 970-330-1071 • FAX 970-330-1252
August 22, 2012
Mr. Jeff Demaske
Journey Homes, LLC
7251 W. 20'hStreet
Building L, Suite 200
Greeley, CO 80634
Re: 421 San Juan Drive
Provincetowne — 3`d Filing
Dear Jeff:
Total Engineering Service, Inc. (TES) conducted a foundation excavation review for a single-
family residence under construction at the above -referenced site located in Fort Collins,
Colorado.
The footings were excavated to a layer of moderately expansive sandy silty clay material,
which is similar to those soils described in the Final Geotechnical Exploration Report,
Provincetowne Subdivision, Third Filing, Phase 2, Fort Collins, Colorado, prepared by Total
Engineering Service, Inc. and dated August 8, 2012.
The footings need to be over excavated a minimum six feet (6') in depth. The expansive clay
soils should be replaced with well compacted structural fill. TES did not encounter
groundwater within three feet of the proposed footing elevation. The soils supporting the
footings will then be a low expansive material. Based on the soil conditions encountered
within three feet of the footing level, a continuous spread footing may be designed and
constructed in accordance to the above mentioned Final Geotechnical Exploration Report.
Please contact me if you have any questions concerning this matter.
Sincerely,
TOTAL ENGINEERING SERVICE, INC.
Tom Cope, P.E.
President
12-106
�'• �S122// Zr Q
T
E S
TOTAL ENGINEERING SERVICE, INC.
1601 37" ST. • EVANS, COLORADO 80620 • 970-330-1071 • FAX 970-330-1252
August 27, 2012
Mr. Jeff Demaske
Journey Homes, LLC
7251 W. 20th St., Bldg L, Ste. 200
Greeley, CO 80634
RE: Compaction of Fill Review
421 San Juan Drive
Provincetowne, Td Filing
Fort Collins, Colorado
Dear Jeff:
As requested, Total Engineering Service's staff obsE
excavated foundation excavation. We visually foun
compliance with the recommendations/of the foun(
August 22, 2012.
Please give me a call if you have any questions.
Sincerely,
TOTAL ENGINEERING SERVICE, INC.
Tom Cope, P.E.
President
12-106
ted the compacted fill placed in the over -
the fill to be complete and in substantial
tion excavation observation letter dated
7
E S
TOTAL ENGINEERING SERVICE, INC.
1601 37th ST. • EVANS, COLORADO 80620 • 970-330-1071 • FAX 970-330-1252
August 28, 2012
Mr. Jeff Demaske
Journey Homes, LLC
7251 W. 20th St., Bldg L, Ste. 200
Greeley, CO 80634
RE: Footing and Foundation Observation
421 San Juan Drive
Provincetowne — 3`d Filing
Fort Collins, Colorado
Dear Jeff:
As requested, Total Engineering Service, Inc. staff observed the footing and foundation
formwork and reinforcing steel for the above referenced single family residential property and
found them to be in substantial compliance with the design drawings prepared for this
structure. The "Wer" electrical ground system was placed in the footing and meet the
requirements of Article 250.52(A)(3) of the 2008 National Electrical Code (NEC). The footings
were observed on August 27, 2012 and the foundation walls were observed on August 28,
2012.
Please give me a call if you have any questions.
Sincerely,
TOTAL ENGINEERING SERVICE, INC.
�Z
Tom Cope, P.E.
President
12-106
h4,�r
'. 114� <�
i
T
E S
TOTAL ENGINEERING SERVICE, INC.
1601 37" ST. • EVANS, COLORADO 80620 • 970-330-1071 • FAX 970-330-1252
August 29, 2012
Mr. Jeff Demaske
Journey Homes, LLC
7251 W. 20th St., Bldg L, Ste. 200
Greeley, CO 80634
RE: Foundation Damp Proofing
421 San Juan Drive
Provincetowne — 3rd Filing
Fort Collins, Colorado
Dear Jeff:
As requested, Total Engineering staff observed the foundation damp proofing and found it to
be complete and in substantial compliance with the design drawings prepared for this structure
at the date of the inspection.
Please give me a call if you have any questions.
Sincerely,
TOTAL ENGINEERING SERVICE, INC.
Xd
Tom Cope, P.E.
President
12-106
T
E 4S
TOTAL ENGINEERING SERVICE, INC.
1601 37" ST. • EVANS, COLORADO 80620 • 970-330-1071 . FAX 970-330-1252
September 6, 2012
Mr. Jeff Demaske
Journey Homes, LLC
7251 W. 20th Street
Building L, Suite 200
Greeley, CO 80634
Re: Foundation Subsurface Drainage System
421 San Juan Drive
Provincetowne — 3`d Filing
Fort Collins, Colorado
Dear Jeff:
As requested, Total Engineering Service (TES) staff observed the foundation subsurface
drainage pipe and sump pit perimeter drain system. TES found it to be complete and in
substantial compliance with the design drawings prepared for this structure at the date of this
observation.
Please give me a call if you have any questions.
Sincerely,
TOTAL ENGINEERING SERVICE, INC.
Tom Cope, P.E.
President
12-106
,*"pp0 R,
VOy��O
Z4995-1