Loading...
HomeMy WebLinkAbout421 SAN JUAN DR - DISCLOSURES - 11/3/2012 (2)BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Phone: 970-223-7090 Date of Test: 11-3-12 Test File: Journey Homes 421 San Juan BD Customer: Journey Homes Greeley, CO 80634 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: Technician: Paul Higman Building Address: 421 San Juan Fort Collins, CO 80525 1112CFM (+/-1.1%) 2.16 ACH 0.31 CFM per ft2 floor area 120.7 in2 ( +/- 3.2 %) Canadian EgLA @ 10 Pa 66.1 in2 (+/- 5.4 %) LBL ELA @ 4 Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 98.9 ( +/- 8.8 %) Exponent (n) = 0.618 ( +/- 0.024 ) Correlation Coefficient = 0.99612 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 69.6 CFM 0.14 ACH 2. Estimated Design Infiltration Rate: Winter: 111.7 CFM 0.22 ACH Summer: 63.5 CFM 0.12 ACH 3. Recommended Whole Building Mechanical 66.2 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 11-3-12 Test File: Journey Homes 421 San Juan BD Building Conditions Inside Temperature: 69 deg F Heating Fuel: Gas Outside Temperature: 64 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 3.0 Volume: 30804 ft3 Ventilation Weather Factor: 0.87 Surface Area: Energy Climate Factor: 17.0 Floor Area: 3624 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments House wrt Garage =-48.2pa House wrt Mech room = Electric water heater BUILDING LEAKAGE TEST Page 3 Date of Test: 11-3-12 Test File: Journey Homes 421 San Juan BD Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -1.2 n/a +/- 0.00 -50.2 36.1 1092 1087 -1.1 Ring A -45.2 32.4 1036 1031 0.3 Ring A -40.1 29.0 982 977 2.5 Ring A -35.0 218.8 876 872 -0.3 Ring B -29.2 163.9 759 755 -2.9 Ring B -25.4 147.3 720 717 0.7 Ring B -20.0 107.2 615 612 0.5 Ring B -1.0 n/a +/- 0.00