HomeMy WebLinkAbout615 SPARROW PL - DISCLOSURES - 10/1/2012 (2)� I;03) 2
City of Fort Collins
Residential Mechanical Systems Performance Testing Submittal Form � f 2—
This farm Is a record of tasting targets and results, with Pass/Fail outcomes. For Information on measurement tools and testing techniques, see th "Residontial New
Construction Mechanical Systems Testing Guide:' The guide and this form may be periodically updated; check the Building Services web site for the current version.
This form must be completed and signed by an "Approved Agency;' and submitted to Building Services as a requirement for receiving a C.O.
Color key
Addros
Builds
HVAC cantracto
Bath exhaust
Measured value to
Target or limit
compare withtarget o
limit
Pass
� , Caution
Other data
Testing dates)
1 j
Airflow, measurement method — low box = Flaw collar
1 Paaalve flow hood Pitot tube traverse
Temperature of air thra ug Indicated now to Volumetric flow multipli r
measurement lo0 74 F @ 5000', air temperature I.098
Measured Exhaust Alrflow
Minimum
Operation
Arnow
Indicated
Volumetric Flow
Exhaust Pickup Location
Intermittent or
Flow
PassFail
Continuous
Requirement
(CFM)
(CFM 5,000')
CFM 5000'
master Bath
termB —Contin
50 Cfm
55
60.39
bil
❑`
U.L. Bath
ntermit _Conan
50 Cfm
69
75.762
wdr
x1elermu _ Conlin
50 Cfm
52
57.096
❑,
Intermit Conlin
❑
❑:..
_ Intermit _ Conlin
❑
❑
Intermit Contin
❑
Intermit Contin
❑
❑)
Intermit Contin
❑
❑,
Kitchen exhaust
Oven fuel Gas
ctric
Exhaust airflow Minimum exhaust airflow requiremenlCFM 5000'
Operation _ Intermittent _ Continuous
Measured airflow
Airflow measurement method — Flow box _ Flow collar
Passive Oaw hood _ Pilot tube traverse
Temperature of air through Indicated flow to Volumetric flow multiplier
measurement tool F t{� @ 5000', air temperature
Indicated flow) yFM Volumetric flowCFM 5000' ❑ Pass ❑ Fail
Testing notes (fan speed, maskim,
flow out of range....
Mechanlcal systems Pertormanu Teenng Suamlaal FmmV10120321 1 of 6
Systems other than substructural floor exhaust
Minimum exhaust airflow requirement
55
FM 5000'
Indicated to
Measured Airflow
Volumetric
Design Airflow
Measurement
Measurement Location a
Flow
Indicated Flow Volumstric
(CFM 5000')
Method
Air Temperature (F)
Multiplier
(CFM) Flow
Pass/Fall
(CFM 5000'
��//�
- ew box
Total exhaust airflow
— Passive flow hood
Flow
_ collar
/,., ..11
Pilot tube traverse
.43q"
1.098
69
75.762
_ Flow collar
Total supply airflow
— Pilot tube traverse
r1CD
LLP
_ Flow box
Passive flow hood
For systems In which supply airflow is circulaledylathe air handler fan, fan speed for measuremen Hest Cooling Continuous fan
Balanced airflow In balanced systems
Average of measured suppl
and exhaust flow CFM 5000,
❑ Pass
Substructural floor exhaust
Design airflow
[:::�C FM 5000'
Target flow rang to CFM 5000'
(average •b 15%)
❑ Fell
Measured airflow
Airflow measurement metho — Flow box — Flow collar
Passive flow hood Pilot tube traverse
Temperature of air through �Indicated now to Votumebic flew multiplier
measurement tool F ® 5000', air temperature
Indicated flow CFM Volwnetric flow CFM 5000' ❑ Pass 13 Fail
a 'e t-,T & -:y ^,�� •,t an +' T, _ ~sue k, P A
Temperature fair Indicated fieve to Valtanatlic flow Mullion r
throug measurement ,�F �..
House conditioned floor area
Maximum Allowed Duct Leakage Measured Ducl Leakage
Test Parameter and Conditions
Normalized Leakage
(CFM25I 100 sf)
Absolute
Leakage
(CFM25)
Indicated Flow
(CFM25)
Volumetric
Flow
(CFM25 5000')
Measurement
Timing
Air Handler
Paas/Fall
Total leakage
Rough -in
Excluded
4
El--
,.
Total leakage
Rough -in
Included
6
❑
.
Total leakage
Complete
Included
12
El
,.
Leakage to outdoorsG
implete
Included
6
196 132
35.13
01[.
Mechanical Systems Performance Testing Submltlerfo V20120321 2 of 6
Filter type
Bran urolator f312 Type I styl Dis osable Thicimes 3° Inches MERV (optional) =
Static pressures (OPTIONAL)
Mode: Healing
_ coming
Continuous Fan
Fan speed lap p - +
Humidifier bypass_ Open Closed
All registers open LIP AC coil
_ Zone dampers open ^Ella '
P=_
LP filter =
P.-
L
P=+
P Total ESP =
Cooling: Measured air flow�ndoor coil usag flow grid
Design cooling airflow, 134� CFM 5000' Target airflow limle (design+/- 15%) 1139 to 1541 CFM 5000'
Measured airflow
Cooling fan speed tap Med-High
Temperature of air throng
measurement too 76 F
NSOP 21.2 Pa TFSOP r21.0 Pa
Measured airflow, no adjustments or correction QCFM
v.h,.st,ictjo4 1383.48 1CFM soon' pass
Heating: Gas manifold pressure
Flow grid plate si.4 _ 14
Indicated flow to Vofumetrlc flow multipII Jrl 098
Q 5000', air temperature
Flow Resistance Correction
Adjusted (indicated)
❑- Fail
OEM manifold pressur 33 IWC Target manifold pressure limits(apse+/-5%) 1 to3. IWC
specification , 5000
Measured manifold pressur 3,4 IWC �., Pass ❑'< 'Fail
Heating: Temperature rise
OEM temperature rise limit 1' D to O F
Measured temperature rise
Return air '76 F
Temp rise 53 f
Supply air Zi F
0-, Pass Fall
Caution: Temp rise within
10 F of top of range
Mechanical Systems Performance Testing SubmiltdFo V2e12e321 3 of 6
(This section under development, not yet being enforced)
Supply air flows (This section under development, not yet being enforced)
Pressure balance
Pressure difference limit, room -to -core
Room
Measured pressure
drop(P2)
pass
Fell
Master Bedroom
4-2.2
`"
Q =
Bedroom 2 front next to stairs
-2.1
4d
❑
Bedroom 3 front end
-1.2
&-
0
❑
❑"
❑
❑`
M,h.a I.al Systems Pedormance Testing Subminalfo V20120321 4.16
Worst -case depressurization testing p/"..}.,1- ` V— _4_�_A ,
House setup �J��
Tested appliances
_ p of bath fans on These doors are closed:
_ Vented range hood on
_ Clothes dryer on
Air handier on
Other fan. on
Appllanc
Typi
Locatku
CAZ pressure
BPI depressurization limit Pa wrt outside
Measured net CAZ depress urizatlonPe wrt outside
ON (less negative) ( Caution (more negative)
Spillage
BPI maximum limit seconds
Measured spillage duration seconds
Pass - duration not exceeding limit
Draft pressure
BPI limit Pa win CAZ
Measured Pa wrt CAZ
Pass a pressure more negative than limit
CO concentration in undiluted flue gas
BPI maximum limit ppm
Measured CO ppm
Pass = CO level not exceeding limit
Caution - CO level 25 to 100 ppm
_ Dratt-hood
Induced -draft
_ Draft -hood
Induced -draft
_ Draft-hootl
Induced -draft
100
100
100
❑
ass
10 all
❑
Pass
it
❑
ass
❑; all
❑
autlon
❑
Caution
❑
faution
Mechanical Syelema Performance TaeOng aubml ebiP. V20120321 5 al a
System controls operating per design Intent
Approved Agency(I
Name (print)
Tine
Company
Signature and Date
Local exhaust
❑ +
Whole -horse ventilatlm,
Substructural floor exhaust
❑
G
Heating
❑ '�
Cooling IF
❑
❑`''
acnmclan pefforming Ins ecclon au u"suT.M uvwnrr;
Paul Higman
Energy Rater
Thermal Concepts/ Allied
HVAC contractor (Fort Col'ns license holder
A.
Name (print)
Title
Company
Signature and Date
u
Mechanical Systems Fetlormana ream, Submlulfe V2e140321 6 of 6