Loading...
HomeMy WebLinkAbout456 SAN JUAN DR - DISCLOSURES - 10/13/2012 (2)BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Phone: 970-223-7090 Date of Test: 10-13-12 Technician: Paul Higman Test File: Journey Homes 456 San Juan_1444 BD Customer: Journey Homes Building Address: 456 San Juan Fort Collins, CO 80525 Greeley, CO 80634 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: 798 CFM (+/- 1.5 %) 2.11 ACH 0.28 CFM per ft2 floor area 59.4 in2 (+/- 6.4 %) Canadian EgLA @ 10 Pa 26.2in2(+/-10.7%)LBLELA@4Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 28.3 ( +/- 17.1 %) Exponent (n) = 0.854 ( +/- 0.046 ) Correlation Coefficient = 0.99414 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 20.8 CFM 0.05 ACH 2. Estimated Design Infiltration Rate: Winter: 33.2 CFM 0.09 ACH Summer: 19.7 CFM 0.05 ACH 3. Recommended Whole Building Mechanical 58.9 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 10-13-12 Test File: Journey Homes 456 San Juan_1444 BD Building Conditions Inside Temperature: 71 deg F Outside Temperature: 40 deg F # of Stories 1.0 Wind Shield: M # of Occupants # of Bedrooms: 3.0 Volume: 22745 ft3 Surface Area: Floor Area: 2888 ft2 Design Winter Wind Speed: 9.0 mph Design Summer Wind Speed: 7.0 mph Comments House wrt Garage = 47.2pa House wrt Mech room = Electric water heater Heating Fuel: Gas Heating Fuel Cost: Heating Efficiency: Heating Degree Days: 6020 Cooling Fuel Cost: Cooling SEER: Cooling Degree Days: 287 Ventilation Weather Factor: 0.87 Energy Climate Factor: 17.0 Design Winter Temp Diff: 69 deg F Design Summer Temp Diff: 16 deg F BUILDING LEAKAGE TEST Page 3 Date of Test: 10-13-12 Test File: Journey Homes 456 San Juan_1444 BD Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure , Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -0.9 n/a +/- 0.00 -50.5 187.8 812 788 -0.7 Ring B 45.4 162.6 756 734 1.4 Ring B 40.1 121.7 655 636 -2.1 Ring B -34.5 105.1 609 591 3.8 Ring B -31.4 78.8 528 512 -2.3 Ring B -25.0 54.3 439 426 -0.7 Ring B -0.8 n/a +/- 0.00