Loading...
HomeMy WebLinkAbout627 SPARROW PL - DISCLOSURES - 7/16/2012 (3)BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College Ave Fort Collins, CO 80525 Phone: 970-223-7090 Date of Test: 7-16-12 Technician: Paul Higman Test File: Journey Homes 627 Sparrow BD Customer: Journey Homes Building Address: 627 Sparrow Fort Collins, CO 80525 Greeley, CO 80634 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: Infiltration Estimates 1000CFM (+/-0.9%) 2.67 ACH 0.41 CFM per ft2 floor area 121.8 in2 ( +/- 2.5 %) Canadian EgLA @ 10 Pa 71.1 in2 (+/- 4.3 %) LBL ELA @ 4 Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 117.4 ( +/- 7.0 %) Exponent (n) = 0.548 ( +/- 0.019 ) Correlation Coefficient = 0.99686 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 1. Estimated Average Annual Infiltration Rate: 82.1 CFM 0.22 ACH l 2. Estimated Design Infiltration Rate: Winter: 120.2 CFM 0.32 ACH Summer: 68.3 CFM 0.18 ACH 3. Recommended Whole Building Mechanical 37.2 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 7-16-12 Test File: Journey Homes 627 Sparrow BD Building Conditions Inside Temperature: 76 deg F Outside Temperature: 82 deg F # of Stories 2.0 Wind Shield: M # of Occupants # of Bedrooms: 3.0 Volume: 22477 ft3 Surface Area: Floor Area: 2413 ft2 Design Winter Wind Speed: 9.0 mph Design Summer Wind Speed: 7.0 mph Heating Fuel: Gas Heating Fuel Cost: Heating Efficiency: Heating Degree Days: 6020 Cooling Fuel Cost: Cooling SEER: Cooling Degree Days: 287 Ventilation Weather Factor: 0.87 Energy Climate Factor: 17.0 Design Winter Temp Diff: 69 deg F Design Summer Temp Diff: 16 deg F Comments House W RT Garage -47.3 pa House W RT Mechanical Rm = Elect water heater J BUILDING LEAKAGE TEST Page 3 Date of Test: 7-16-12 Test File: Journey Homes 627 Sparrow BD Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -1.5 n/a -50.2 268.8 970 -45.3 256.1 947 -40.5 213.8 866 -35.1 178.6 792 -30.4 152.3 732 -25.1 124.3 662 -20.2 96.9 585 -1.4 n/a 975 -1.1 Ring B 952 2.3 Ring B 871 -0.3 Ring B 796 -1.1 Ring B 736 -0.7 Ring B 666 0.3 Ring B 588 0.6 Ring B +/- 0.00 +/- 0.00