HomeMy WebLinkAbout4615 DUSTY SAGE LOOP - DISCLOSURES - 7/5/2006THERMAL
ENVIRONMENTS FOR 4
i a
CONCEPTS
MASCO CONTRACTOR SERVICES Eftar' P.O.(9 0)223-7090-Fax(970)2223877098
July 5, 2006
RE: Rutt Construct
1001 A E. Harmony Rd
4503
Ft. Collins CO 80525
Project: 4615 Dusty Sage Loop unit #3
Score: 84.5
Type: Final
_905_06X�6
The following is a list of the trade-offs used to achieve the 2005 energy code requirement.
AREA
VALUE
NOTES
IFa—cing
East
The "front" of the house is toward the garage
ACH
.35 NACH
Verified with a blower door test
Basement
walls
12.4
R-11 to the furred walls and R-19 to the walk -out portion. With R-13 in the rims and no insulation
on the exposed concrete
Crawls ace
N/a
Slab
edge/floor
R-0
No slab edge insulation
Floors
4.18
Exterior walls
R-13
R-13 to all exterior walls above grade
Rims
R-13
Windows
2.86
All windows are low-e field verified
Ceilings
R-38
Blown attic
Heating
system
92.1 AFUE
Cooling
system
13 SEER
Hot water
.58
Standard water heater with heat traps
Misc
Sincerely,
Paul Higman
Energy Rater