Loading...
HomeMy WebLinkAbout4809 S COLLEGE AVE - MISCELLANEOUS - 2/8/2006No Text V�d to coo 529 4j?0 9 S' . C t kqc inum Existing Wall 1' Plastic Trims • Painted Alum 3116' Thk. Tran White Acrylic F Transluscent Y as noted 15 mm White N Tubing On Glass Supports Electrode Cap .060 Aluminum .060 aluminum Suitable Pastenei By Others 3M 3630-167 Bright Blue Graphics 6 Letters — applied to Face White Outline QL-2220 QL-2230, QL-2420 & QL-2420-T Scale: 3/8"=1'-O" 13'-3" Neon Illuminated Letters B Hand Symbol Logo QL-2420 T Non-Illunninated Acrylic " Tire and Auto Center " Letters " (1) New Sign Required 1" plastic trim cap painted aluminum 3mm Implex Acrylic letters w/ Vinyl applied on the }ace 3M 3630-97 Bristol Blue Acrylic mounting block 3116" x 3" Ig. threaded pins ( 10-24 ) aluminum w/ ® Epoxy or silicone adhesive Ave.:4Aetter Typ.Section Detail APPROVED BY. CUSTOMER "r DATE............................................................ APP OVED AS PER LAYO UT/SPECIFICATIONS INDICATES) ORASNOTED ON THISDOCUME34T GENERAL CONTRACTOR TO PROVIDE ALL NECESSARY STRUCTURAL SUPPORT & ELECTRICAL SUPPLY TO INSTALL SIGNAGE AS SHOWN ON BUILDING. INDIVIDUAL NEON ILLUMINATED LOGO & LETTERS ARE THRU-WALL MOUNT & REQUIRE ACCESS AT REAR OF INSTALLATION POINT FOR FINAL ELECTRICAL HOOK-UP. CONTACT OMNIPLAN PRIOR TO ORDERING SIGNS TO VERIFY SIGNAGE LOCATIONS & MOUNTING DETAILS. OMNIPLAN WILL ALSO PROVIDE ELECTRICAL REQUIREMENTS. RVICE QL 2220 - FASCIA SIGN 2'-0" HAND SYMBOL ILLU QL 2430-C - FASCIA SIGN T-6" WORDMARK ILLUM. QL 2030 - WALL SIGN NON41-LUM. PLAQUE LVstosgTI QUICK LANE - DESIGN CONTROL DOCUMENTS - USA 1748 zoo one Road West SPRADLEY BARR FORD The purpose of the Design Control Documents Is to convey the design intent only. They are not to be used to Suite obtain building permits or for construction. Construction documents are to be prepared by a licensed design Courtice, Ontario, Canada Fort Collins, CO professional wilting to accept the responsibility for proper application and =nphanos wdh applicable Federal, L1 E 2T1 sY State or Local rubs, regulations, requirements and laws. Any specifications derived from these plena should Tel: 805 434 2446 REVISED EXTERIOR ELEVATION be verified by as parties involved. No representation is made by Omniplan as to the compliance of the foregoing design and/or drawings with all applicable Federal, State or Local rules, regulations, requirements or laws. Fax: 905 434 2666 Date: Oct 17/05 1 By: B.G. PrOj. NO.: 3420 sq EXISTING BUILDING TO REMAIN SCALE 1/8"=1r-Orr • _ w1 I I pal