Loading...
HomeMy WebLinkAbout6719 HOLYOKE CT - DISCLOSURES - 12/19/1997City of Fort Collins ENERGY SCORE Home Energy Rating Program - Version 2.0.4 FINAL *************************************************************-60TTERATAR**** ENERGY RATING RESULT ******************************************************************************* Owner: KEM HOMES Address: 6719 HOLYOKE Zip: 80525 Phone: 223-4900 Builder: KEM HOMES Model: 2366 Devel: RIDGEWOOD HILLS Reference #: Data File: Run Date: Year Built: Rating Firm: Site Rater: Rating Date: 240677 A:6719-HOL.DAT 12-19-1997 1997 RICHMOND ASSOCIATES DONALD RICHMOND 12-13-97 ******************************************************************************* ENERGY SCORE: (Least Efficient) *********** * G - 85 *********** G - 85 v ---- I----I----I---- I ---- I ---- I ---- I ---- I ---- I ---- I (Most G-0 10 20 30 40 50 60 70 80 90 100 Efficient) ******************************************************************************* This program is offered by the City of Fort Collins as an aid in comparing the energy efficiency of homes. The information provided does not constitute any warranty, express or implied, as to the presence or lack of energy features in this house, the heating fuel used in the house and its costs, or the actual energy consumption or performance of the house. City of Fort Collins ENERGY SCORE Home Energy Rating Program - Version 2.0.4 DETAILED ENERGY REPORT FOR RATED BUILDING Owner: KEM HOMES Address: 6719 HOLYOKE Zip: 80525 Phone: 223-4900 Builder: KEM HOMES Model: 2366 Devel: RIDGEWOOD HILLS BUILDING CHARACTERISTICS Conditioned Space Area: 3748 sq ft Total Glazing Area: 401 sq ft Air Infiltration Rate: 0.40 AC/h Eff. Thermal Capacity: 8100 Btu/F Util. of Direct Solar: 0.66 Reference #: 240677 Data File: A:6719-HOL.DAT Run Date: 12-19-1997 Year Built: 1997 Rating Firm: RICHMOND ASSOCIATES Site Rater: DONALD RICHMOND Rating Date: 12-13-97 ENERGY SCORE *********** * G - 85 *********** BUILDING ENERGY SUMMARY Load Efficiency ---------- Energy --------------- Consumed Fuel Cost Energy Cost KBtu/sf % KBtu/sf MMBtu --------- $/MMBtu ----------- $/sf Gas Space Heat 19.1 90.0 21.2 79.5 4.24 0.09 Gas Water Heat 6.2 54.0 11.5 43.2 4.24 0.05 Building TOTAL 25.3 32.7 122.7 0.14 COMPONENT SUMMARY: SPACE HEATING Heat Loss Coeff Gross Heat -------------------- Loss Useful Gains Net Heat Load Ceilings/Roofs Btu/hr-F o KBtu/sf o o KBtu/sf o ------------- KBtu/sf MMBtu Frame Walls 39.4 122.5 6 18 1.6 5.1 5 17 0.3 4 1.3 4.8 Masonry Walls 6.2 1 0.3 1 0.5 0.0 5 0 4.6 17.4 Rim/Band Joists 14.6 2 0.6 2 0.0 0 0.2 0.9 Windows/Skylights 208.6 31 8.7 29 5.3 58 0.6 3.4 2.3 Sunspace - - - - 12.7 Doors 13.9 2 0.6 2 0.0 0 0.6 2.2 Foundation Walls 49.0 7 2.0 7 0.0 0 2.0 7.6 Frame Floors 13.6 2 0.6 2 0.0 0 0.6 2.1 Slab Floors 30.1 4 1.3 4 0.0 0 1.3 4.7 Crawl Sp/Unht Bsmt 4.5 1 0.2 1 0.0 0 0.2 0.7 Infiltration 176.6 26 7.3 24 0.0 0 7.3 27.5 Envelope TOTAL 678.9 100 28.3 93 6.1 67 22.1 82.9 Active Solar Spc Ht - - Internal Gains Duct/Pipe Losses 0.0 - 0 - - 3.0 33 -3.0 -11.4 Furnace Losses 2.1 7 0.0 0 2.1 7.9 Space Heating TOTAL 30.4 100 9.2 100 21.2 79.5 COMPONENT SUMMARY: WATER HEATING Gas 11.5 KBtu/sf = 43.2 MMBtu Solar _ _ Water Heating TOTAL 11.5 KBtu/sf = 43.2 MMBtu ENERGY SCORE Data Listing Date: 12-19-1997 Input Worksheet: A:6719-HOL.WS Reference Number: 240677 1. GENERAL INFORMATION Property Owner's Name 1 KEM HOMES Property Address 2 6719 HOLYOKE Zip Code 3 80525 Telephone Number(s) 4 223-4900 Home Builder's Name 5 KEM HOMES Model Name or Number 6 2366 Development Name 7 RIDGEWOOD HILLS Energy Rating Company Building Plan Rating: Energy Rater's Name Energy Rating Date Site Visit Rating: Energy Rater's Name Energy Rating Date 8 RICHMOND ASSOCIATES 9 DONALD RICHMOND 10 10-23-96 11 DONALD RICHMOND 12 12-13-97 2. BUILDING STRUCTURE Year Constructed 13 1997 Area of Conditioned Space (sq ft) 14 3748 Housing Type (1-5) 15 1 Apartment Only: Level Type (1-3) 16 0 Floors On or Above Grade (1-2) 17 2 Foundation Type(s) (1-7) 18 6 Roof Entry Line # [19] [20] [21] 3. CEILINGS/ROOFS Gross Area (sq ft) 19a 1178 20a 454 21a 0 Ceiling/Roof Insulation (R-Value) 19b 40 20b 38 21b 0 Ceiling Type (1-2) 19c 1 20c 2 21c 0 4. RIM AND BAND JOISTS Area Joist Location Joist Insulation (sq ft) (1-4) (R-Value) 22a 206 22b 1 22c 16 23a 57 23b 2 23c 13 5. FRAME OR BRICK VENEER WALLS Wall Entry Gross Area Wall Location Wall Insulation Line # (sq ft) (1-4) (R-Value) [24] 24a 1888 24b 1 24c 16 [25] 25a 408 25b 2 25c 13 [26] 26a 33 26b 3 26c 0 [271 27a 0 27b 0 27c 0 ENERGY SCORE Data Listing Input Worksheet: A:6719-HOL.WS Date: 12-19-1997 Reference Number: 240677 6. MASONRY WALLS ABOVE GRADE Wall Entry Gross Area Const. Type Wall Location Wall Insulat Line # (sq ft) (1-4) (1-4) (R-Value) [28] 28a 110 28b 1 28c 1 28d 13 [29] 29a 13 29b 1 29c 2 29d 13 [30] 30a 12 30b 1 30c 4 30d 13 7. WINDOWS (INCLUDING DOOR GLAZING) Area Orientation Glazing Type Wall Entry (sq ft) (1-6) (1-21) Line #(24-30) 31a 70.3 31b 3 31c 4 31d 24 32a 61.9 32b 5 32c 4 32d 24 33a 12.6 33b 1 33c 4 33d 24 34a 174.8 34b 3 34c 4 34d 24 35a 8.2 35b 2 35c 4 35d 24 36a 8.2 36b 4 36c 4 36d 24 37a 14.7 37b 3 37c 4 37d 24 38a 31.9 38b 5 38c 9 38d 28 Area (sq ft) 39a 18.4 40a 0 41a 0 42a 0 Orientation (1-6) 39b 3 40b 0 41b 0 42b 0 8. SKYLIGHTS Pitch Glazing Type (?/12) (1-21) 39c 8 39d 4 40c 0 40d 0 41c 0 41d 0 42c 0 42d 0 9. DOORS (OPAQUE DOOR AREAS ONLY) Roof Entry Line #(19-21 39e 19 40e 19 41e 19 42e 19 Area Door Insulation Storm Door Wall Entry (sq ft) (R-Value) (l.yes, 2.no) Line #(24-30) 43a 20 43b 4.4 43c 2 43d 24 44a 17.8 44b 1.7 44c 2 44d 25 45a 8.8 45b 1.7 45c 2 45d 24 ENERGY SCORE Data Listing Input Worksheet: A:6719-HOL.WS Date: 12-19-1997 Reference Number: 240677 10. FOUNDATION WALLS BELOW GRADE Construction Depth Type (1-4) Length Below Grade Wall Location Wall Insulat (ft) (ft) (1-2) (R-Value) 46a 1 46b 145 46c 7 46d 1 46e 13 47a 1 47b 23 47c 3 47d 2 47e 19 48a 0 48b 0 48c 0 48d 1 48e 0 11. FRAME FLOOR Floor Area Insulation Floor Location (sq ft) (R-Value) (1-3) 49a 286 49b 21 49c 1 50a 66 50b 1.5 50c 2 51a 0 51b 0 51c 0 12. SLAB FLOORS (ON OR BELOW GRADE) Exposed Floor Area Perimeter Perimeter Insulation (sq ft) (ft) (R-Value) 52a 1142 52b 145 52c 0 53a 0 53b 0 53c 0 Under Slab Depth Width of Insulation Insulation Below Grade Under Slab (R-Value) (ft) (ft) 52d 0 52e 7 52f 0 53d 0 53e 0 53f 0 13. INTERIOR FINISH Drywall Thickness (0.5 to 1 in.) 54 Uncarpeted .5 Floor Slab (l.yes, 2.no) 55 2 Uncarpeted Floor Slab Area (sq ft) 56 0 Uncarpeted Floor Slab Thickness (in.) 57 4 14. ADDITIONAL MASS Mass Type Mass Area Mass Thickness (1-3) (sq ft) (in.) 58a 0 58b 0 58c 0 59a 0 59b 0 59c 0 ENERGY SCORE Data Listing Date: 12-19-1997 Input Worksheet: A:6719-HOL.WS Reference Number: 240677 15. INFILTRATION Type of Volume of Infiltration Infiltration Cond. Space Measurement Value (cubic ft) (1-3) (ACH or sq.in) 60 29855 61 1 62 .4 16. HEATING EQUIPMENT Heating Heating Electric System Type System AFUE Furnace Input Demand Control (1-7) (o) (1000's Btu/h) (l.yes, 2.no) 63 1 64 90 65 125 66 2 17. DUCTS AND PIPES Duct or Pipe Area in Attic above Insulation (sq ft) 67 0 Attic Duct Insulation (l.yes, 2.no) 68 0 Duct or Pipe Area in Crawl Space or Unheated Basement (sq ft) 69 0 Crawl Space or Unheated Basement Duct Insulation (l.yes, 2.no) 70 0 18. DOMESTIC HOT WATER Water Heater Type (1-4) 71 1 Water Heater Efficiency (o) 72 54