HomeMy WebLinkAbout4926 PYRENEES DR - DISCLOSURES - 1/9/200801/09/08 08.:59 FAX 9702237098 THERMALCONCEPTS 12002
Residential Energy Code
Insulation Disclosure Form
ob Address: 4926 PYRENEES
General Contractor: PLS HOMES
Air Sealing Contractor: Allied Insulation
Instructions
This disclosure form is to be signed by the insulation contractor or representative of the general contractor_
Please type or print, except for the signature. Complete the information in the appropriate spaces provided.
If components vary, make multiple entries to describe them.
One copy of this form must be provided to the Building and Zoning Department prior to the C.O.
One copy of this form must be mad available to the original home buyer.
Inculatinn
^
Location
Materials
Fiber lass
Thickness
3.5
Rated
R-Value
13
Est. Sq ft
Notes
2x4 walls/Boxsills
Fiberglass
5.5
19
2x6 walls/Kneewalls
Exterior walls
Fiber lass
12.25
38
Ceiling area not accessible
Attic
Fiber lass
3.5
11
Garage ext walls
Basement ext walls
Fiberglass
3.5
13
Fiber lass
10
30
Overhan s/cantilever
Certification
I/We Certify that the above- listed insulation was Installed in the building at the locations In conformance with the current requirements of the
Fort Collins Residential Energy Code, and that it was Installed in accordance whh the "Insulation Guidelines" published by the City of Fort Collins.
Person CertitjTyfn Job: .lames Hart
Signature.: //�.,� Date: / Phone (970)962-9011
Aftsiness/ Pho e: �`