HomeMy WebLinkAbout4926 PYRENEES DR - SPECIAL INSPECTIONS - 9/6/2007Engineers Plannars Surveyors ArcM1itects P • St9 September 4, 2007 Project No. PROGLI-7H4D-09-705 PLS Homes, Inc. 4190 N. Garfield Avenue Loveland, Colorado 80538 Gentlemen: Enginaal-i"g Loveland 970-667-6286 Toll Free 866-379-6252 Fax 970-667-6298 www.landmarkltd.com 3521 West Eisenhower Blvd. Loveland, Colorado 80537 We have observed the open excavation at Lot 17, Cottonwood Ridge, a subdivision of Fort Collins, Colorado. (a.k.a. 4926 Pyreness Drive) The subject excavation was observed on September 4, 2007. The exposed soil indicates a balanced spread footing type foundation system is suitable if designed in accordance with the recommendations contained in the soils report performed by Terracon, Project No. 20025046, dated December 17, 2002. No water was encountered to a depth of 6 feet. All footings shall be 8" thick unless otherwise noted. A properly installed perimeter subdrain is required to help protect all below grade habitable space from water infiltration. Very truly yours, Landmark Engineering Ltd. Lance Bublitz Project Engineer PERMIT NUMBER: #B0705767 �p REGlST �G THO4r.Fipt< 3 177 �r The above has been reviewed and approved bne.G �T 35177. , Colorado P.E. Engineers Planners Surveyors i\rChlte Cts Gaotectanica! E • • SEP 17 2007 September 12, 2007 Project No. PROGLI-7H4D-09-735/740 PLS Homes Inc. 4190 N. Garfield Avenue Loveland, Colorado 80538 F 1-1 g' 11-1 e e r-I r) g Loveland 970-667-6286 Toll Free 866-379-6252 Fax 970-667-6298 www.landmarkltd.com 3521 West Eisenhower Blvd. Loveland, Colorado 80537 RE: Observation of Footings & Steel Reinforcing for Lot 17, Cottonwood Subdivision, Fort Collins, Colorado.-(a.k.a. 4926 Pyreness Drive) Gentlemen: We observed footings, pads and the reinforcing steel placed in the footings, pads and foundation walls at the subject site on September 11, 2007 and September 12, 2007 . All observed footings, pads and steel reinforcing met the specifications for size, type and installation as per foundation plan prepared by Landmark Engineering Ltd, Project No. PROGLI-7H413-09-327, dated July 30, 2007. Rebar tie-in for grounding electrode was verified to be connected to the foundation rebar and extended to above grade level for electricians to connect to at time of electrical rough -in. Very truly yours, Landmark Engineering Ltd. Lance Bublitz Project Engineer PERMIT NUMBER: #B0705767 The above report has been reviewed and approved by W 35177. p iRp POG T H OA�F,p .3 177 1iIMMIJ Engineers Planners Surveyors Architects G®otech n ical • SEP 2.0 2007 September 18, 2007 Project No. PROGLI-7H4D-09-742 Engir-ieering Loveland 970-667-6286 Toll Free 866-379-6252 Fax 970-667-6298 www.landmarkltd.com 3521 West Eisenhower Blvd. Loveland, Colorado 80537 PLS Homes Inc. 4190 N. Garfield Avenue Loveland, Colorado 80538 RE: Damp Proofing and Perimeter Drain Material and Installation Observation for Lot 17, Cottonwood Subdivision, Fort Collins, Colorado. (a.k.a. 4926 Pyreness Drive) Gentlemen: Personnel from this office observed the applied damp proofing and perimeter drain installation and materials on September 18, 2007. The observed drain installation, damp proofing, and perimeter drain system material was found to be in general compliance with the recommendations set forth in • the foundationplan, Project No. PROGLI-7H4D-09-327, dated July 30, 2007, prepared byLandmark Engineering Ltd. Please contact our office if you have further questions. Sincerely, Landmark Engineering Ltd. Larry Miller Ge ogist RMIT NUMBER: #B0705767 g00 REG7� �G'TH� f . 35177 v; • This letter has been reviewed and approved by Wayne ado P.E. 35177.