HomeMy WebLinkAbout644 GILGALAD WAY - DISCLOSURES - 9/10/1998Fort Collins residential energy code 7/96
Mechanical systems disclosure form
Job address:
General contractor.
Mechanical contractor.
Space heating system
Location
Fuel
Type
-Manufacturer
Modei #
Input capacity
I kBtuh or kW
AFUE or
HSPF
Space cooling system';:
Location
Fuel Type
Manufacturer
Model #
Input capacity
kBtuh or kW
I SEER
I
I
Water heating system
Location
Fuel Type
Manufacturer
Model #
Input capacity
kBtuh or kW
Energy I Storage
Factor volume
I
I
j
I
Certification
IiWe certify that the above-listed.equipmentwas installed in the building at the above locations in conformance with he
current requirements of the City of Fort Collins Residential Energy Code and Mechanical Code, and that it was installed in
accordance with manufacturer's instructions. INVe certify that any ductwork has been installed in conformance with
the current requirements of the City of Fort Collins Residential Energy Code and Mechanical Code.
Certified by: Robert *filler Phone: 970-223-8873
Business firm: Northern Colorado Air, IncDate:
Address: 1823 E. Harmony Rd. Signature:
o r
Instructions
This disclosure form is to be signed by the mechanical dontractor or representative of the general contractor.
Please type or print, except for the signature.
If there are multiple systems serving any function, make multiple entries to describe them.
One copy of this form shall be provided to the Building and Zoning Department at final inspection.
One copy of this form shall be provided to the homebuyer.
Fort Collins residential energy code 7/96
Air sealina disclosure form
Job address:
General contractor: Paai%,�
Air sealing contractor: Ids j s Iw
A: Prescriptive path
Me certify that the air sealing requirements specified in the current City of Fort Collins Residential Energy Code
have been completed in this building, in accordance with the "Air Sealing Checklist' published by the City of Fort Collins.
Certified by: fwtu tinyg Phone: 'Z23 1927
Business firm: RZ>AKta� COIJ Date:
Address: (f+ 41 (jajj • Signature:
B;1 Performancepath
Me certify that this building has met the air leakage performance threshold specified in the current
City of Fort Collins Residential Energy Code, in accordance with the "Blower Door Test Procedures," published
by the City of Fort Collins.
Testing contractor:
Date of test:
CFM5O: Air flow through the blower door at 50 Pascals pressure difference (cfm)
Volume: Volume of home (cu. ft.)
ACH5O: Air change rate per hour at 50 Pascals pressure difference
ACH50 = (CFM50 x 60) / Volume
The performance threshold for code compliance is ACH50
not exceeding 5.0 ac/h
Certified by: Phone:
Business firm: Date:
Address: Signature:
or
Part A is to be signed by the air sealing contractor or representative of the general contractor.
Part B is to be signed by the blower door testing contractor or representative of the general contractor.
The "Blower Door Test Report" or equivalent documentation must be attached.
Please type or print, except for the signature.
If components vary, make multiple entries to describe them.
One copy of this form shall be provided to the Building and Zoning Department at final inspection.
One copy of this form shall be provided to the homebuyer.
.sMtWM23—e 4W
Fort Collins residential energy code 7/96
Insulation disclosure form
Job address: (/+ �tL(Ts�n AJ�
General contractor:
Insulation contractor:
Insulation
Flat or vaulted ceilings
with attics above
Ceilings with enclosed
rafter cavities
Frame walls and rim/band
joists —to exterior
Frame walls and rim/band
joists — to attic, garage
Frame floor - cantilever
Frame floor -over garage or
crawl space
Slab-cn-grade (0.12")
Crawl space walls
Basement walls
Rated
•1M
Location
Certification
Me certify that the above -listed insulation was installed in the building at the above locations in conformance with the
current requirements of the City of Fort Collins Residential Energy Code, and that it was installed in accordance with
the applicable "Insulation Installation Guidelines" published by the City of Fort Collins.
Certified by: $24,uj '&s lJs Phone: 14,a -VA
Business firm: s1 coj!�J Date:
Address: 54r1 Signature:
Instructions
This disclosure form is to be signed by the insulation contractor or representative of the general contractor.
Please type or print, except for the signature.
If components vary, make multiple entries to describe them. ma,c.eirssa-aowr
One copy of this form shall be provided to the Building and Zoning Department at final inspection.
One copy of this form shall be provided to the homebuyer.
/) %,MERICAN ROCKWOOL, INC. 28 LB'. SAG'
P.O. Box C, Nolanville, Texas 76559 (817) 698-2233 * P.O. Box 880, Spring Hope, NC 27882 (919) 478-5111
BLOWING WOOL INSULATION CERTIFICATION
PNEUMATIC INSTALLATION
R-Value' Minimum Maximum Net •• Weight Per. Bags Per
(at mean temperature Thickness Coverage Square Foot 1,000 Sq. Ft
at 75° F
To obtain an Installed insula- Contents of bag The weight per sq. ft. The number of bags
insulation resistance tion shall be not shall not cover of installed insulation per 1,000 sq. h. shall
value of: less than: more than: shall be not less than: be not less than:
(R-Value) (inches) (sq. tt.) (tbs. pensq. ft.) (no. of bags)
R-60 17.70 10.65 2.63 93.9
R-50 14.75 12.78 2.19 78.2
R-49 14.45 13.02 2.15 76.8
R-44 12.98 14.58 1.92 68.6
R-40 11.80 16.09 1.74 62.2
R-38 11.21 16.87 1.66 59.3
R-33 9.73 19.44 1.44 51.4
R-30 9.62 21.88 1.28 45.7
R-26 8.33 25.22 1.11 39.6
R-22 7.05 29.79 .94 33.6 -
R-19 6.09 34.57 .81 28.9
'R' Value is a measure of insulating ability. 'R' means resistance to heal flow. the higher the 'Fr value, the greater the insulation value.
" See Framing Correction chart on other for gross coverage.
SIDE WALL SPECIFICATIONS - SPRAY SYSTEM (OPEN BLOW)
ibs cmhnh M me Wr hwhlhd In pprn wA1 veu by pMumatic epltlpmar wM WMINII wll mm1Er bts Ih r IIIMO (B) muss 9f wplpha sM [avenges shpwn W. h M lb. Wps.
R-14.5 3'k 25.7 1.17 38.9
R-15.0 3% 24.8 1.21 40.3
R-22.7 5%2 16.4 1.83 61.0
R-33.0 8.0 11.2 2.68 89.3
V vnnmspnrp anhaar = a lnu2upa eaa sawsNe ahry aowrspv M w Pm bw.
BUILDER'S AND APPLICATOR'S STATEMENT AND SIGNATURE
This is to certify that qe igulation has b e Installed in conformance with theor�e rements indicated in this card to
provide a value of R = using bags of insulation to cover y Q_ square feet area.
DATE BUILDER AA•-- BUIIDER IGNATURE
DTvTE APPLICATOR BSnI�W�RE -
ram, �j