Loading...
HomeMy WebLinkAbout457 RIVA RIDGE DR - MISCELLANEOUS - 1/23/2000Jan 24 01 12:16p SRRF (S70) 266 - 100S p.13 DATE 01/23/00 SARA'S ENERGY SCORING 1225 W Prospect P-14 FT. COLLINS CO 80526 (970)495-9922 CUSTOMER: Kaufman and Brood / 457 Riva Ridge ,91A/ Ft. Collins Cc BUILDING CONDITIONS: Interior Temp = 65 F Volume = 17658 CU. Ft Number of Stories = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: Exterior Temp = 45 F Above Grade Surface Area = 0 Sq. Ft. Number of Occupants = 2 House Pressure Fan Pressure CFM %Error Fan Configuration Ring B 57 240 901 1.2 51 221 864 -0.3 Ring B 42 200 821 -0.6 Ring B 34 179 776 -1.1 Ring B 29 166 747 -1.0 Ring B 21 150 710 1.7 Ring B Correlation Coefficient Flow Coefficient Exponent r = .9916 C = 332.20 n = 0.244 Results: Air Flow B 50 Pascals 862 CF!j ±/= —T. ACH50 (Air Per Hour) /PZZC12) Effective Leakage Area (LBL) _ Equivalent Leakage Area (CANADA) _ 132.04 Square Inches +/- 3.7% 171.01 Square Inches +/- 2.2% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 64 CFM = 31.8 CFM/OCCUPANT = 0.22 AIR CHANGES PER HOUR